Pultruded grating is the long-span answer. Continuous glass roving pulled through a heated die builds bearing bars whose stiffness a moulded panel cannot reach, so walkways can clear 1.2 m and beyond without intermediate steel.

ISO 9001BS EN 1370645+ Countries20+ YearsCut-to-Size
Definition

What Is Pultruded FRP Grating?

A pultruded FRP grating is an open-mesh panel whose bearing bars are pultruded composite profiles rather than moulded plastic.

Pultrusion pulls continuous E-glass roving through a resin bath and then through a heated steel die, where the profile cures to its final cross-section. Glass runs the full length of the bar in one direction, so the section is uniform and its stiffness is predictable from the section properties — there is no chopped-strand randomness in the load path.

The bars are then assembled into a panel with a locking system that holds a fixed pitch, and the top flange becomes the walking surface. This is the panel you specify when the span, not the material, is the constraint.

Process

How Pultrusion Turns Roving into a Bearing Bar

The line runs continuously: creels feed roving, a resin bath wets it out, a preforming die removes excess resin and sets the shape, and the heated die cures the profile. Pullers haul it at constant speed and a flying saw cuts to length. Because the die sets the section, wall thickness and tolerances stay inside a few tenths of a millimetre along the whole bar.

The practical consequence for a grating buyer is repeatability. Two panels ordered six months apart from the same die have the same depth and the same section modulus, so a load calculation written for the first batch still applies to the second.

Profiles

I-Bar and T-Bar: Which Profile to Specify

An I-bar carries a top and a bottom flange, so it works in both directions and behaves well under a concentrated load placed mid-span. Standard depths run from 25 mm to 76 mm. It is the profile most pultruded walkway specifications name first.

T-bar carries a single top flange with a vertical web below, in depths from 25 mm to 50 mm. Where the panel has to sit low, or the deck is being laid over an existing bearer grid, the T-bar keeps the overall build-up down.

The two are not interchangeable in a calculation. Send the span, the load and the deflection limit and we will tell you which section works and at what pitch — specifying by depth alone is how overloaded walkways get built.

Geometry

Mesh, Open Area and What You Actually Walk On

Open area is fixed by the bar pitch, not by the bar depth. A wider pitch drains better and lets more light through; a tighter pitch gives a more continuous walking surface and stops small tools falling through.

The walking surface is the top flange of the bearing bar. It is supplied plain for dry indoor duty, or gritted with embedded silica for wet, oily and outdoor installations. Grit is applied during manufacture, so it does not peel off in service the way a painted-on coating does.

Load Data

Indicative Allowable Uniform Load by Span

The figures below are indicative allowable uniform loads for a simply supported single span at a deflection limit of L/200, taken from our own sizing tool. They are a starting point for a layout, not a substitute for the project calculation.

Values are in kN/m². Interpolate between spans only after checking the governing limit — on most walkways it is deflection, not strength.

Panel type600 mm span900 mm span1200 mm span
Pultruded T-bar 38 mm35189
Pultruded T-bar 50 mm482614
Pultruded T-bar 65 mm623520
Deflection

Deflection Limits: L/200, L/150 and L/100

Deflection usually decides the panel, not ultimate load. A walkway that feels springy gets rejected at inspection even when it is strong enough. L/200 is the common specification for a personnel walkway; L/150 appears where a slightly softer deck is acceptable; L/100 is used for covers and non-walking spans.

Because deflection scales steeply with span, a panel that passes at 900 mm can fail outright at 1,200 mm at the same load. That is the single most common reason a moulded panel gets rejected late and a pultruded one gets specified instead.

Resin

Resin Systems and Chemical Exposure

Orthophthalic polyester is the general-purpose grade for atmospheric exposure and fresh water. Isophthalic polyester adds humidity and mild chemical resistance and is the usual choice for wastewater and coastal sites.

Vinyl ester is specified for acids, hypochlorite, brine and splash zones where polyester would blister. Phenolic is the grade for low smoke and low toxicity in tunnels, rolling stock and enclosed spaces.

The resin is the part of the specification that actually decides service life. Tell us the chemical, the concentration and the temperature, not just the industry, and the grade follows from that.

Fire

Fire Performance and the Paperwork Buyers Ask For

Fire performance is a documented property, not a marketing word: buyers ask for a classification to EN 13501-1 and, in rail and tunnel work, for smoke and toxicity data as well.

We hold a third-party ASTM F3059 test report (report 211122012SHF-001, issued 2021) and can supply it with a quotation on request. Certification to ISO 9001 (GB/T19001-2000 idt ISO9001:2000, registration 01708Q11888R0S) covers the manufacturing system behind it.

Fabrication

Cut-to-Size, Notches, Penetrations and Stair Treads

Panels are cut on a saw or a CNC bed to the drawing, with notches for bearers, cut-outs for risers and openings for cable trays. Cutting a pultruded panel exposes the bar ends, so any cut edge that sits in a chemical or wash-down area gets a resin coat.

Stair treads are a separate fabricated item: a pultruded or moulded tread with a nosing, drilled for the stringer, and gritted on the walking face. They are quoted per step, not per square metre.

Fixing

Clips, Bolts and Bearer Spacing

A panel is only as good as its fixing. Standard practice is a proprietary clip at each bearing bar on each bearer, with the clip matched to the bar profile so the panel cannot walk. Bolted fixing is used where the deck is subject to uplift or vibration.

Bearer spacing must match the span used in the calculation. A panel sized for 900 mm bearers that gets installed on 1,200 mm centres is an overload, and that mismatch is what a site inspection finds.

Comparison

Pultruded vs Moulded: When Each Wins

Moulded wins on price per square metre, on integral anti-slip texture, and on robustness to abuse — it is a one-piece panel with no assembled joints. For spans up to about 900 mm at normal walkway loads, moulded is the right answer.

Pultruded wins as soon as the span, the concentrated load or the weight budget pushes past what a moulded panel can do, and it wins clearly where the deck has to be carried over a trench, a channel or a piece of plant without extra steel.

Applications

Where the Longer Span Pays Back

The commercial case for pultruded grating is almost always a reduction in support steel. Every bearer you delete is steel that is not bought, not galvanised, not installed and not inspected for the next twenty years.

Typical installations: platform decks over pipework, trench and channel covers with vehicle loading, maintenance walkways on tanks and silos, rooftop PV access routes, and bridging in retrofit work where adding steel is not an option.

Specification

Specification Checklist for a Quotation

Send these seven items and the quotation comes back line by line instead of as a round number: panel type and profile (I-bar or T-bar), depth, bar pitch, resin grade, panel size and cut list, gritted or plain top, and the fixing clips with bearer spacing.

If the design is not fixed yet, send the span, the load, the deflection limit and a sketch of the layout. We will size the panel and return a recommendation with the load case written out.

FAQ

Pultruded FRP Grating — Frequently Asked Questions

What is the difference between pultruded and moulded FRP grating?

Moulded grating is poured into a matched mould as one piece, with an integral anti-slip surface and no assembled joints; its span is limited by the panel itself. Pultruded grating is assembled from continuous pultruded bearing bars, which makes it stiffer for the same depth and lets it clear longer spans. Price per square metre is higher for pultruded; the payback comes from the support steel it removes.

What clear span can pultruded grating reach?

For a 50 mm pultruded T-bar, a personnel walkway at L/200 is typically good to around 1.2 m, and to about 2.4 m where a looser deflection limit is accepted. Beyond that the answer is intermediate bearers rather than a deeper panel. The span is always confirmed by calculation for the actual load case.

Which is stronger, I-bar or T-bar?

It depends on the depth and the load direction, not on the letter. An I-bar has flanges top and bottom, so it resists a concentrated load from either side; a T-bar puts its material in a single top flange and web. For a given depth the I-bar usually gives the higher section modulus, but the number that matters is the one in the calculation for your span.

Do you supply cut-to-size panels?

Yes. Send the cut list or a dimensioned drawing and panels are sawed or CNC-cut with notches for bearers and openings for risers and trays. Cut edges that will sit in chemical or wash-down service are given a resin coat before dispatch.

Which resin should I use for a chemical plant?

Vinyl ester for acids, hypochlorite, brine and splash zones; isophthalic polyester for milder chemical exposure and humidity; phenolic where low smoke and low toxicity are specified. Give us the chemical, the concentration and the operating temperature and we will confirm the grade in writing.

Is pultruded grating slip resistant?

It is when you specify the gritted top. A plain pultruded top flange is not a slip-resistant surface in wet or oily conditions, and it is the wrong choice for a walkway. Grit is embedded during manufacture, not painted on, so it stays through the service life.

What panel size do pultruded panels come in?

Panels are assembled to order. The common production size is 1220 x 3660 mm, and other sizes are produced by changing the bar length and the number of bars, so a non-standard panel does not need a new mould — which is why custom sizes are cheaper in pultruded than in moulded.

How is pultruded grating fixed down?

With a proprietary clip at every bearing bar on every bearer, matched to the bar profile so the panel cannot move. Bolted fixing is used where uplift or vibration is present. Bearer spacing must match the span used in the load calculation.

What documentation comes with a quotation?

Itemised pricing by panel, the resin datasheet for the grade quoted, and a fire classification to EN 13501-1 on request. The third-party ASTM F3059 report (211122012SHF-001) and the ISO 9001 certificate (registration 01708Q11888R0S) are available with the quotation.

What are the minimum order and lead time?

The minimum order is 10 m² for standard panels. Lead time runs from 12 to 36 working days depending on resin grade, fabrication content and quantity; cut-to-size work and phenolic resin sit at the longer end. Oversized panels, custom colours, new moulds and specialty resins are quoted with a separately confirmed schedule.

Next Step

Request a Pultruded FRP Grating Quotation

Send the span, the load, the resin and the panel schedule. You will get an itemised quotation, a sizing recommendation and the documentation your approval pack needs.

Request a Quote → Grating Calculator

NANTONG ZEALL NEW MATERIALS CO., LTD. · Direct manufacturer · ISO 9001 · BS 4592 / BS EN 13706 documentation on request

Square Bar Grating

Pultruded FRP square bar grating: profiles and load direction

A Pultruded FRP square bar grating panel is built from continuous pultruded rectangular or square load bars, spaced 12.5, 20 or 32 mm centre-to-centre, and tied together by glass cross rods at 50 mm pitch. The bars are the depth direction—all the fibers run along the bar, which is why the panel carries load like a one-way slab. Standard T-bar and I-bar depths run 25, 38, 50 and 65 mm; the 38 mm panel weighs about 87 kg per 1220×3660 sheet and carries 25 kN/m² uniformly distributed (m38), or 35 kN/m² on the p38 profile.

Compared with moulded grating, pultruded square-bar panels have deeper, stiffer bars and therefore longer spans—typically up to 1.5 m between supports on walkway duty—while staying lighter than steel bar grating. They are the default for industrial walkways, trench covers, platform floors and equipment access where a predictable one-way load path is required. Pair them with FRP structural profiles for the support frame and FRP clips for the fixing.

Pultruded FRP square bar grating vs moulded grating

Moulded grating is a two-way mesh with fibres in both directions; pultruded grating is a one-way slab with deep bars. For pedestrian walkways over 1 m spans, pultruded wins on deflection and dead load; for foot-traffic floors over short spans with frequent wheeled trolleys, moulded is often more economic. The mesh opening also differs: pultruded bars leave long narrow slots, which is fine for walkways but can trap small items on a working floor. See the comparison on the FRP grating overview page.

Open Mesh

Open mesh pultruded FRP grating: drainage, slip and light transmission

Open mesh pultruded FRP grating leaves roughly 65–75 % of the panel area open, depending on bar width and pitch. That open area is what makes it the default for external walkways, stair treads, trench covers and cooling-tower platforms: rain, snow, oils and wash-down water fall straight through; leaves, gravel and small debris fall through too; natural light reaches the floor below, which saves lighting energy in covered galleries. The mesh also lets fire suppression water pass, which matters in racking and mezzanine installations.

Because the bars are deep—38 mm and up—the open mesh does not feel flimsy underfoot. A grit-top is applied to the wearing face of each bar, so even with 70 % open area the walking surface is slip-resistant. Standard mesh openings are 38×38 mm (tight for footwear), 38×152 mm (open, drainage-friendly) and 19×152 mm (anti-fall). For panel sizes and cutting, see FRP grating panels.

Open mesh pultruded FRP grating for walkways and trenches

Trench covers are the single biggest application: the panel bridges the trench, drains through the mesh, and can be lifted out for access with a grating hook. Because pultruded bars run along the span, the trench width determines the bar depth—25 mm for narrow foot-traffic trenches, 38 mm for pallet-truck crossings, 50/65 mm for vehicle crossings. All panels clip to the surrounding frame; none are welded.

Fixing

Clip for pultruded FRP grating: fixing without welding

A Clip for pultruded FRP grating is the standard way to lock a panel to its support frame. There are two families: stainless-steel saddle clips that grip the bottom of the bar and bolt to the support angle, and composite (FRP) push-in clips that snap between the bar and the cross rod. Neither family requires drilling through the wearing surface, neither produces sparks on the structure, and both can be undone for panel removal. Welding is never used on FRP—it destroys the resin skin and the fiber matrix—so clips are the only code-compliant fixing.

The stainless saddle clip is the workhorse: 316 grade for coastal and chemical service, 304 grade for inland. It bolts to a pre-drilled hole in the support angle, which means the steel under-frame can be galvanised or FRP. The composite push-in clip is used where even stainless would corrode—chlorine rooms, battery bays, pulp bleaching halls—and where the specifier wants a fully non-conductive fixing. See the full range on the FRP clips product page, and how clips pair with FRP grating supply packages.

Clip for pultruded FRP grating: stainless and composite options

Selection is by environment, not by price. Inland, dry, foot-traffic walkways use 304 saddle clips; coastal, wash-down and chemical use 316; battery rooms and chlorine atmospheres use composite. Each clip is sized to the bar depth—25, 38, 50 or 65 mm—and supplied with matching bolts and washers. We ship clips loose in bags or pre-installed on the panels depending on the project.

FAQ

Pultruded FRP Grating: Frequently Asked Questions

What is the difference between Pultruded FRP square bar grating and moulded grating?

Pultruded panels have deep, one-way load bars (25–65 mm) and carry load like a slab over long spans; moulded panels have a two-way mesh and are lighter but shorter-spanning. For walkways over 1 m and trench covers, pultruded is the default; for short-spanning foot floors, moulded is often cheaper. Both are available in iso-poly, vinyl ester and phenolic.

How much open area does Open mesh pultruded FRP grating leave?

Typically 65–75 %, depending on bar width and pitch. The 38×38 mesh leaves ~65 %, the 38×152 mesh leaves ~75 %. Open area is what makes it the default for external walkways, trench covers and cooling-tower platforms where rain, wash-down water and fire-suppression water must pass through.

How is a Clip for pultruded FRP grating chosen?

By environment: 304 stainless for inland dry walkways, 316 stainless for coastal and wash-down, composite FRP for battery rooms and chlorine atmospheres. Clips are never welded—welding destroys the resin skin—and are sized to the bar depth (25/38/50/65 mm). MOQ 10 m², lead time 7–35 working days; clips ship with the panels or loose.

Naming

The Same Pultruded Panel, Five Spellings: Fiberglass, Fibreglass, GRP and FRP

Pultruded fiberglass grating, fiberglass pultruded grating, fibreglass pultruded grating, fiberglass reinforced plastic pultruded grating and glass reinforced plastic pultruded grating

Every phrase in that list names one article: continuous glass rovings pulled through a resin bath and a heated die, assembled into load-bearing bars with cross rods. Pultruded fiberglass grating is the wording most buyers use; fiberglass pultruded grating simply moves the adjective; fibreglass pultruded grating is the British spelling of the same word; fiberglass reinforced plastic pultruded grating and glass reinforced plastic pultruded grating are the expanded forms that appear in specifications, datasheets and tender schedules. There is no difference in bar depth, resin system, mesh pitch or load table.

What does change with the wording is the standard cited alongside it. European schedules tend to quote BS EN 13706 for the pultruded profile and EN 124 for trench covers; North American schedules quote ASTM E84 Class 1 for surface burning and ASTM F3059 for the fiberglass structure. We supply against either, with mill certificates and the ISO 9001 certificate (01708Q11888R0S) issued to NANTONG ZEALL NEW MATERIALS.

Pultruded fiberglass bar grating and the pultruded FRP grating panel: bars, then panels

Pultruded fiberglass bar grating is the component view: T-bar or I-bar load bars at 25, 38, 50 or 65 mm depth, spaced 12.5–32 mm apart, tied by glass cross rods at 50 mm pitch. The pultruded FRP grating panel is the finished view: a 1220 mm × 3660 mm sheet cut to the layout, edge-banded and clipped down, carrying 35 kN/m² at p38 and 48 kN/m² at p50 uniformly distributed.

Specifiers sometimes quote bars and panels separately because the bars travel as bundles and the panels as crated sheets. We quote both ways, and we cut to drawing so the installer receives numbered panels rather than full sheets — MOQ 10 m², lead time 7–35 working days. Fixings are on the FRP clips page; support frames on FRP structural profiles.

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to [email protected]. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: [email protected]