50 mm T-Bar Pultruded FRP Grating
A deep T-bar section for three to four metre spans, used where a long clear opening must be crossed without added steelwork.
Technical specifications
| Type | Pultruded FRP grating, T-bar section, deep bar |
|---|---|
| Bearing bar depth | 50 mm (2 in) |
| Top flange width | 15 mm |
| Bar pitch | 38 mm standard; 50 mm pitch for open-area critical layouts |
| Open area | about 40% (clear 15 mm) or about 50% (clear 19 mm) |
| Unit weight | about 17 kg/m² at 40% open; about 15 kg/m² at 50% open |
| Standard panel | 1220 x 3660 mm, cut to size; longer panels on request |
| Resin systems | Isophthalic polyester; vinyl ester; phenolic for fire-critical and offshore work |
| Surface | Concave or grit; smooth available for wash-down decks |
| Fixing | Heavy-duty saddle and clip with SS316 bolts; end fixings at every bearer |
Load and span guidance
| Support span | Indicative UDL, 40% open | Indicative UDL, 50% open | Deflection basis |
|---|---|---|---|
| 2.5 m | about 620 kg/m² | about 540 kg/m² | L/200 |
| 3.0 m | about 420 kg/m² | about 365 kg/m² | L/200 |
| 3.5 m | about 300 kg/m² | about 260 kg/m² | L/200 |
| 4.0 m | about 220 kg/m² | about 190 kg/m² | L/200 |
Indicative only, for a simply supported single span under uniform load. Long-span pultruded decks are normally governed by deflection, so the deflection limit rather than the material strength decides the section. Confirm the allowable load against our certified table before release for construction.
When depth beats extra steel
Every additional bearer under a walkway costs steel, fabrication, coating and a crane lift. A 50 mm section removes one or two bearer rows from a typical three to four metre platform, and the extra 4 kg/m² of grating is usually far cheaper than the frame it replaces. This is the economic argument for the deep bar, and it is the one that wins most often in retrofit work where the existing frame cannot be extended.
The deep T-section is also the practical answer for vibration and walking comfort. Deflection under a walking person falls roughly with the cube of the depth, so the deck feels solid rather than springy, and the panel is less prone to the edge abrasion that appears where a light deck flexes against a fixed handrail post. Where the client specifies L/300 or a 150 kg point load at mid-span, the 50 mm depth usually satisfies both without a change of resin.
Where it fits
- Long-span process platforms and pipe rack access
- Rooftop and cooling tower walkways with limited support points
- Offshore and marine decks with vinyl ester or phenolic resin
- Tank farm and terminal platforms crossing pipe trenches
- Heavy-duty stair landings and stringer-connected treads
Deep panels are heavy enough that two people should lift them with a spreader rather than by the bar ends. Bearers must be level within about 3 mm over the panel length, because a deep bar is less forgiving of a twisted frame than a 25 mm section.