38 mm I-Bar Pultruded FRP Grating
The I-section at 38 mm depth: full platform-span capability with the twist resistance that heavy industrial traffic demands.
Technical specifications
| Type | Pultruded FRP grating, I-bar section |
|---|---|
| Bearing bar depth | 38 mm (1.5 in) |
| Section | I profile with top and bottom flange |
| Bar pitch | 38 mm standard; 25 mm pitch available for dense layouts |
| Open area | about 40% (clear 15 mm) or about 60% (clear 23 mm) |
| Unit weight | about 14.5 kg/m² at 40% open; about 12.5 kg/m² at 60% open |
| Standard panel | 1220 x 3660 mm, cut to size |
| Resin systems | Isophthalic polyester; vinyl ester; phenolic for fire-critical work |
| Surface | Concave standard; quartz grit for ramps and spillage areas |
| Fixing | M-clip or saddle with SS304/SS316 bolts; end clips at every bearer |
Load and span guidance
| Support span | Indicative UDL, 40% open | Indicative UDL, 60% open | Deflection basis |
|---|---|---|---|
| 2.0 m | about 600 kg/m² | about 500 kg/m² | L/200 |
| 2.5 m | about 380 kg/m² | about 315 kg/m² | L/200 |
| 3.0 m | about 255 kg/m² | about 210 kg/m² | L/200 |
| 3.5 m | about 175 kg/m² | about 145 kg/m² | L/200 |
Indicative figures for one simply supported span with uniform load. Point loads, trolley wheels and any concentrated plant load are checked separately against the certified table. Where the deck is open to wind or carries ice and snow, that load case must be added to the design.
Where the deck takes real industrial traffic
This is the section that survives a working platform rather than a viewing platform. The lower flange keeps every bearing bar in line when a drum is set down between two bars, when a trolley wheel crosses the deck at an angle, or when a panel is only lightly fixed at its edges. In practice the difference shows up as the deck still being flat after five years of use, with the bars evenly spaced instead of drifted.
It also simplifies the design conversation. At 12.5 to 14.5 kg/m² and three to three and a half metres of span, one section covers walkways, landings and most platform decks on a site, so the client is not maintaining three different grating items in stores. Standardising on one section is a maintenance saving that rarely appears in the quotation but always appears in the stores list.
Where it fits
- Chemical and petrochemical process platforms
- Pump stations and wastewater galleries with trolley access
- Mining and mineral processing walkways
- Marine terminal and jetty decks, vinyl ester resin
- Food and beverage platforms under wash-down conditions
Panels should be laid so the bearing bars run parallel to the main traffic direction, which puts the stiffer axis under the walking load. Joints are placed over a bearer and fixed with a saddle at each side of the joint, not with a single clip shared between two panels.