FRP Grating Panel Layout Calculator
How many panels does the deck take, how much gets cut away, and what will it weigh. Enter the area and the stock panel size and the tool does the arithmetic, in both orientations, and picks the one that wastes less.
Stock panel sizes
Molded grating is molded in fixed press sizes, and the standard panel is 1220 x 3660 mm, which is 4 x 12 ft. That single fact drives most layout decisions: it is 4.47 square metres per panel, it is more than two people can carry at 38 mm thickness, and it does not divide neatly into metric deck dimensions.
Pultruded grating is made to order in the panel length, so the layout question shifts from cutting stock to ordering the right length. Ask for a cut list before the order is released if the deck is irregular.
| Panel | Area | Notes |
|---|---|---|
| 1220 x 3660 mm (4 x 12 ft) | 4.47 m² | Standard molded press size, usually stocked |
| 1000 x 3000 mm | 3.00 m² | Common export size, easier to handle |
| 900 x 2700 mm | 2.43 m² | Smaller panel for tight access routes |
| Custom | varies | Pultruded panels are made to the ordered length |
Work out the layout
Panel layout and offcut
Enter the deck area and the stock panel size. The tool works out how many panels the area takes in each orientation and how much is cut away.
This is arithmetic, not a layout drawing. Panel joints have to land on the support beams, and the beam positions decide the real layout far more than the panel size does. Send the support grid and we will lay it out properly.
Why the arithmetic is not the layout
A panel joint has to sit on a support beam. If the beams are at 1200 mm centres and the panels are 3660 mm long, the panel will overhang or stop short of a beam unless the length is cut to a multiple of the beam spacing. The calculator does not know where your beams are, so it cannot place joints.
The practical sequence is the reverse of what most people expect: fix the beam grid first, then cut the panels to land on it, then check the remaining panel width still gives a sensible number of bars and a safe walkway. Panels cut to a width that cuts through the middle of a bar row lose a bar and the load capacity that went with it.
Where access is the constraint, a smaller panel size often beats a cheaper large panel. A 1220 x 3660 mm panel that has to be craned over a roof edge and lowered through a hatch costs more in rigging than the offcut it saves.
Offcut, scrap and the honest cost
Offcut is the difference between the deck area and the panel area bought. A 6.0 x 12.0 m deck is 72 square metres; in 1220 x 3660 panels laid one way that is 5 columns x 4 rows, 20 panels, 89.3 square metres bought, so 19.4 percent offcut. Rotated, the same deck needs 10 columns x 4 rows, 40 panels, and the offcut gets worse.
Some offcut is reusable on the same project as small platforms, trench covers or stair landings, and some is scrap. Ask for the cut list before ordering and the difference between a 20 percent and a 12 percent offcut is usually a panel size decision, not a negotiation.
The mass figure follows the area bought, not the area used, because you pay for and ship the panels you order.
Assumptions and limits
- Panels are laid in a rectangular grid with no overlap and no allowance for a cutting gap between adjacent panels. Real installations usually leave a small gap at joints, which adds a little area.
- No allowance is made for edge closure, stair openings, penetrations or handrail posts. Those are cut out of the deck area and reduce the utilisable area.
- The tool does not check that a joint lands on a support, that the cut width keeps enough bars, or that the resulting panel is safe to handle.
- Weight figures use nominal unit weight for standard construction, excluding packing.
Related pages
- Weight calculator
- Span and load calculator
- FRP grating price per square metre
- Custom FRP grating and cut to size
- Molded 50 x 50 mm specification