Resin ratings move with concentration, temperature and how the medium contacts the grating: immersion, splash, spray, vapour or washdown. The reference chart lists mid-strength sulfuric and sodium hydroxide plus hypochlorite for iso and VE within their bands; higher heat or concentration drops the grade one step, and immersion is stricter than splash. Cyclic, mixed or critical service needs written review before selection.
- Three drivers: concentration band, thermal band, contact mode (immersion / splash / spray / vapour / washdown).
- Listed rows: sulfuric 10–50 %, NaOH 10–30 %, hypochlorite <15 %, each <40 °C; ratings read at 20–25 °C.
- Immersion is stricter than splash; a listed splash grade does not establish continuous-immersion cover.
1. The three factors that move a resin rating
Concentration decides how aggressively the matrix meets the medium; temperature accelerates uptake and ageing; contact mode sets how long the face stays wet. A resin that tolerates dilute, cool splash may fail in concentrated hot soaking, so the rating has to be read against all three rather than the medium name alone.
The reference basis for every listed row is room temperature, 20–25 °C. As concentration or heat rises above the listed band, the grade moves down one step; a higher-strength liquor or hotter wash therefore needs a fresh compatibility check rather than the listed reading carried forward.
| Listed medium | Concentration | Temperature | Iso | Vinyl ester |
|---|---|---|---|---|
| Sulfuric acid | 10–50 % | <40 °C | C | B |
| Sodium hydroxide | 10–30 % | <40 °C | C | B |
| Sodium hypochlorite | <15 % | <40 °C | C | B |
Ratings reproduce the reference chart at room temperature only. Above the listed concentration or heat, the grade drops one step and needs written confirmation.
2. Contact mode: immersion versus splash
Immersion keeps the panel in continuous contact with the liquor, which is the most demanding mode in this set. Splash and intermittent wetting let the face drain and dry between contacts, so a listed B grade reflects that lighter duty; it does not cover soaking. Spray and vapour sit between the two, with vapour reaching the face continuously even without liquid pooling.
Before matching a resin, state whether the grating is soaked, splashed, sprayed, exposed to fume or washed down on a cycle. A splash rating reused for an immersion duty is a common misread; the panel would need a separate immersion confirmation. Vapour-phase compatibility also follows its own basis and should not be inferred from the liquid row.
3. Counter-examples when the band is ignored
One counter-example is taking a listed splash grade and running the panel under continuous oxidising liquor. The lighter contact basis does not transfer to soaking, and the matrix can soften or blister before the rating would suggest. Another is selecting a resin for an upper-range concentration or hotter wash while keeping the lower-band grade; above the listed band the reading drops and the service must be re-reviewed.
Mixed or cyclic chemistry compounds these effects: a stream that changes strength, temperature or composition between shifts cannot be judged from a single listed row. Where the exposure cycles, blends or sits near the upper band, the panel stays on engineering compatibility review; extending the listed grade to a condition the row does not describe leaves the duty without evidence.
| Mode / condition | Rating implication | Boundary |
|---|---|---|
| Continuous immersion | Strictest contact; needs immersion basis | Splash grade does not cover soaking |
| Splash / intermittent | Listed B-level basis after draining | Does not extend to continuous wetting |
| Spray or vapour | Continuous atmospheric contact | Vapour compatibility confirmed separately |
| Above listed concentration / heat | Grade drops one step | Written check before higher-band service |
| Cyclic or mixed stream | No single listed row applies | Engineering review of the full exposure |
The listed grade assumes the stated concentration, temperature and contact mode; any change to those conditions moves the rating and needs review.
4. Brief fields and order confirmation
The specification brief should carry the exact medium, min/max concentration, min/max temperature and contact type, plus any cyclic or mixed exposure. Record whether residue dries on the face, whether a vapour phase reaches the panel, and the hottest and strongest service points; those extremes drive the rating more than a nominal average.
Before order, confirm the selected resin against the upper concentration and temperature bounds for its grade. The missing evidence — upper bounds for the chosen resin, plus any cyclic or mixed exposure review — must close through factory or engineering sign-off before the walkway is released to duty.
5. Frequently Asked Questions
Which resin suits concentration, temperature and exposure mode exposure on FRP grating?
The family is set by concentration, temperature and exposure mode, concentration, heat and contact type. The reference chart lists this medium within its stated envelope; those ratings apply only to the stated conditions. Ratings assume room temperature; at higher concentration or temperature the grade moves down, and immersion is stricter than splash.
Is concentration, temperature and exposure mode covered by the reference compatibility chart?
Yes, within the listed concentration and temperature envelope. Anything outside the listed conditions moves the grade down and needs a documented review rather than a table read.
Does this resin choice certify food-safe or drinking-water use?
No. Food-contact and drinking-water compliance are not established from the resistance chart. Where the project requires such approval, obtain the matched compliance document and verify it against the destination regulation before ordering.
What changes the resistance rating besides the resin family?
Concentration, heat and contact type all move the rating. At higher temperature or concentration the grade drops one step; immersion is stricter than splash or intermittent wetting.
What must be confirmed before an order for this service?
Provide the exact medium, min/max concentration, min/max temperature and contact type. Critical, hot, concentrated or unlisted exposure needs a written factory confirmation or project-specific test; combined duty stays on technical review.
Reference PDFs: resin-selection-guide.pdf · chemical-resistance-table.pdf