RFQ Configurator v1
FRP Grating Specification Builder
Bundle environment, design load, clear span, deflection basis, build-up, resin, surface, quantity, destination and Incoterm into one specification line. Allowable loads come from the published load table; the tool interpolates between table points instead of inventing figures.
FRP Grating Specification Builder — Build specification
FRP Grating Specification Builder
Bundle environment, design load, clear span, deflection basis, build-up, resin, surface, quantity, destination and Incoterm into one specification line. Allowable loads come from the published load table; the tool interpolates between table points instead of inventing figures.
| Build-up (verified sections only) | 600 mm | 900 mm | 1200 mm |
|---|---|---|---|
| Molded 25 mm, 38×38 mesh | 12.5 kN/m² | 6 kN/m² | 3.2 kN/m² |
| Molded 38 mm, 38×38 mesh | 25 kN/m² | 12 kN/m² | 6.5 kN/m² |
| Molded 38 mm, 50×50 mesh | 22 kN/m² | 10 kN/m² | 5.5 kN/m² |
| Pultruded I-bar 38 mm | 35 kN/m² | 18 kN/m² | 9 kN/m² |
| Pultruded I-bar 50 mm | 48 kN/m² | 26 kN/m² | 14 kN/m² |
| Pultruded I-bar 65 mm (HD) | 62 kN/m² | 35 kN/m² | 20 kN/m² |
Document checklist
FRP Grating Specification Builder
- This tool gives a preliminary selection and budgeting basis only; it is not a structural design. The project engineer must confirm loads, deflection and the applicable standard against the actual support layout.
- Figures are UDL, L/200, simply supported single-span values. Point, line, wheel and cantilever loads are outside this table and must be checked separately.
- Load duration, temperature, chemical attack and impact all reduce real capacity; keep a safety margin. No temperature de-rating table is on file.
- Substituting resin, mesh or a phenolic grade does not inherit the original model's passing result; matching load data is required.
- A food-grade resin system does not by itself establish food-contact certification.
- Any fire report must match thickness, resin and surface; no fire rating is claimed without a matching current report. Expired ABS assessment is not represented as current approval.
FAQ
What does this builder produce?
It bundles environment, load, span, deflection, build-up, resin, surface, quantity, destination and Incoterm into one specification line with the allowable UDL from the published table, the utilization and an estimated order mass, plus a prefilled RFQ message.
How is the allowable load interpolated?
Between the 600, 900 and 1200 mm table points the tool uses log-linear interpolation, the same method as the span-load calculator. Spans below 600 mm and above 1200 mm are blocked to an engineering check.
Can I use it for a point, wheel or line load?
No. The source tables are uniform-load, simply supported single-span values only. Point, wheel, line and cantilever cases need the bar section, load position and bearing detail checked in a stamped calculation.
Why is the total mass marked not calculable?
Some meshes have no catalogue panel areal weight on file. Where the weight is missing the tool reports mass as not calculable instead of estimating it from another row.
Does the builder claim fire performance or food contact?
No. A fire report must match thickness, resin and surface, and no E84 or EN 13501-1 rating is claimed without a matching current report. A food-grade resin system does not establish food-contact certification.
Which resin fits a given chemical?
The resin guide lists isophthalic for wastewater, seawater and mild acid, vinyl ester for strong acid, bleach and caustic, and phenolic for offshore, tunnel and public fire-critical areas. Any medium not listed must be confirmed in writing before order.