FRP Grating Resin & Chemical Compatibility Brief: What to Specify in the RFQ

Material Selection
Direct Answer

The resin matrix is what the chemical touches; the glass roving carries the structural load. Resin selection is driven by the medium, concentration, temperature and exposure mode (immersion, splash or vapour). The resistance ratings in our reference table are indicative at room temperature; anything critical, concentrated, hot or outside the listed media needs a written compatibility confirmation or test before ordering.

  • Ortho / Iso / VE / Epoxy / Phenolic are the resin families we supply; each has a different indicative wet temperature range and chemical envelope.
  • Rating A = suitable for continuous immersion/splash; B = splash and intermittent exposure; C = test required / not recommended.
  • Food-contact, drinking-water and unlisted-solvent compliance are not claimed from this table and require separate evidence.

Why the Resin, Not the Glass, Meets the Medium

E-glass rovings are the structural backbone; the resin matrix seals the glass and forms the surface the chemical contacts. Picking the right resin for the medium and concentration is the most cost-effective corrosion decision in the specification. The families below are summarized from the resin selection guide; figures are indicative for preliminary design.

Resin familyCostIndicative wet temperature limitBest forNot for
Orthophthalic (ortho)Lowest~60 °C wetFresh water, mild alkaline, general useStrong acid, solvents
Isophthalic (iso)Mid~80 °C wetWastewater, seawater, mild acid, moist atmospheresStrong oxidisers, hot solvents
Vinyl ester (VE)Higher~100 °C wetStrong acid, bleach, caustic, fume scrubbersSome ketones, high aromatic solvents
EpoxyHighest~120 °C wetSpecial structural, very aggressive chemical, high temperatureCost-sensitive general walkways
PhenolicHigh~150 °C wet, fire-ratedOffshore, tunnel, public fire-rated areasContinuous strong alkali

Note: Wet temperature limits are preliminary selection ranges, not service guarantees. Confirm any critical, hot or concentrated exposure in writing before ordering.

Reading the A / B / C Resistance Ratings

Ratings are indicative at room temperature (20–25 °C). At higher temperature or concentration, move one grade down. A = suitable for continuous immersion/splash; B = splash and intermittent exposure; C = test required / not recommended. The table below reproduces the reference chemical resistance table for the listed media only.

MediumConc.Temp.OrthoIsoVinyl esterEpoxy
Acetic acid<10 %<40 °CBAAA
Acetic acid>50 %<40 °CCCBB
Sulfuric acid<10 %<40 °CCBAA
Sulfuric acid10–50 %<40 °CCCBB
Hydrochloric acid<20 %<40 °CCBAA
Nitric acid<10 %<40 °CCCBB
Phosphoric acid<50 %<40 °CCBAA
Sodium hydroxide<10 %<40 °CCBAB
Sodium hydroxide10–30 %<40 °CCCBC
Sodium hypochlorite (bleach)<15 %<40 °CCCBB
Ammonium hydroxide<20 %<40 °CCBAA
Seawater / brine—<60 °CBAAA
Mineral oil—<80 °CAAAA
Gasoline / diesel—<40 °CBBAA
Ethanol<50 %<40 °CCCBA
Methanolpure<40 °CCCCB
Acetonepure<40 °CCCCC
Municipal wastewater—<50 °CBAAA

Source: chemical-resistance-table.pdf and resin-selection-guide.pdf. We do not issue a warranty on immersion service without a written medium brief and resin confirmation.

Worked Compatibility Brief

Case 1 — municipal wastewater walkway, below 50 °C, splash and intermittent wetting: the table rates iso, VE and epoxy A; iso is the typical preliminary selection, with VE reserved for heavier sulphide or acidic condensate exposure.

Case 2 — dilute bleach feed area, hypochlorite under 15 %, below 40 °C: VE and epoxy are rated B (splash/intermittent). Continuous immersion in bleach is outside the table envelope and needs written confirmation before specification.

Case 3 — pure acetone or methanol service: ratings are C across most families; do not select a resin from this table alone. Treat as a test-required environment.

Out-of-scope and blocked items. The table does not cover media not listed above, and no rating is assigned to them. Food-contact and drinking-water compliance are not claimed on this page. Compatibility with solvents, external service temperatures, UV aging and long-term immersion beyond the listed conditions requires a written confirmation or a project-specific test report.

Resin Brief Fields for the RFQ

FieldWhat to provideWhy it matters
MediumExact chemical name (and mixture if any)Rating depends on the specific medium
ConcentrationMin / max concentration in %Concentration moves the rating up or down
TemperatureMin / max service temperatureHigher temperature lowers the rating grade
Exposure modeImmersion, splash, spray, vapour, washdownA vs B rating depends on contact mode
Mechanical dutySpan, design load, rolling or pedestrian trafficTies resin choice to the structural selection
Required standardDestination or project standard referenceChecks documentation expectations

Assemble the brief in the specification builder, then review typical sections in the spec series. Reference PDFs: resin selection guide · chemical resistance table.

Frequently Asked Questions

Which resin should I choose for wastewater or seawater?

Isophthalic polyester is the typical preliminary choice for municipal wastewater and seawater below the listed temperature, per the reference table. Vinyl ester is selected for stronger acid, bleach or caustic exposure; confirm critical service in writing.

Can vinyl ester resist every chemical?

No. Vinyl ester covers strong acids, bleach and caustic in the listed range, but some ketones and high aromatic solvents remain outside its envelope. Pure acetone and methanol are rated C and require testing rather than table selection.

Does the table certify food-safe or drinking-water use?

No. Food-contact and drinking-water compliance are not claimed from this table. If the project requires such approval, request the specific compliance evidence and verify it against the destination regulation before ordering.

What changes the resistance rating besides the resin?

Concentration, temperature and exposure mode all move the rating. At higher temperature or concentration, move one grade down; immersion is stricter than splash. Send all three in the resin brief.

Are temperature limits in the resin guide service guarantees?

No. The wet temperature ranges are preliminary selection guides, not guaranteed service limits. Critical, hot or concentrated exposure requires a written compatibility confirmation or test report.

What are the MOQ and lead time?

MOQ is 10 m². Standard production is 15–25 working days after drawing approval; overall 12–36 working days overall. Indicative pricing is USD 15–95/m², depending on resin grade, thickness, surface, quantity and processing.

Need a panel recommendation for your span and load?

Send span, design load, deflection limit, resin and medium. We return a build-up recommendation and the matched load table.

Published: 2026-11-20 | Category: Material Selection | Author: FRP Grating Technical Team