When the process medium, mixture or residue is absent from the reference chemical table, no A/B/C rating may be assigned and selection cannot proceed from a listed row by analogy. These cases are test-required: a documented compatibility review or specimen test closes the missing evidence before specification. Mixtures, vapour phases and concentration ranges must be evaluated on their own composition rather than from any single component.
- Rule: an unlisted medium or blend stays unrated until a written compatibility check or test exists.
- Reference ratings are read at 20–25 °C; no grade is extended to an unfamiliar mixture from a nearby listed acid, alkali or solvent.
- Mixture proportions, vapour phase and concentration/temperature bands belong in the review brief.
1. Why an unlisted medium cannot be rated from the table
The chart covers a defined set of acids, alkalis, oxidisers, solvents and aqueous media under stated strength and temperature. A fluid outside that set has no listed row, so no A/B/C reading can be copied. Assigning one by comparison to a listed neighbour is an unsupported assumption, and the laminate may meet chemistry the reference never assessed.
A custom blend often behaves differently from its parts: reaction, residue concentration or vapour chemistry can shift the matrix load. Treat the unknown as test-required, supply its composition, and let factory or engineering close the compatibility evidence before choosing the family.
| Item | Status for an unlisted medium | What closes the gap |
|---|---|---|
| Listed in reference chart | No row for this medium or blend | Documented compatibility review or specimen test |
| Exposure basis | Actual contact: immersion, splash, vapour or washdown | Min/max concentration and temperature recorded in writing |
| Rating that may be assigned | None; selection remains undecided | Factory or engineering sign-off against tested medium |
| Analogy to a listed component | Not permitted for the unlisted blend | Evaluate the full mixture on its own composition |
A medium absent from the table must not be graded by analogy; treat it as test-required and obtain written confirmation before specification.
2. Evidence to request for the unknown medium
The brief needs the exact chemical identity, mixture proportions, strength range, temperature range and whether contact is soak, splash, spray, vapour or washdown. Note whether residue dries on the face, a vapour phase reaches the panel, or the chemistry cycles between shifts.
A specimen test should mirror real service — strength, heat and contact mode — rather than a milder laboratory cut. The record should state which resin family it covers and the basis it does not extend to, so the order matches tested evidence rather than presumed tolerance.
3. Counter-examples and mixed-stream traps
A typical miss is rating an unknown organic acid from the acetic row, or selecting a blend on the weakest listed component. Mixtures can generate heat, vapour or residue single-component rows do not describe; carrying over a component rating gives false cover. Combining two listed ratings and assuming the blend inherits the better one is also invalid — readings cannot be added this way.
Unlisted oxidiser–acid–alkali streams, solvent blends and heavy residues sit outside the table. If exposure is unknown or mixed, the panel waits on a compatibility test or engineering assessment; extending a listed grade to an unlisted fluid leaves the service without evidence. Closing that gap precedes the resin choice.
| Mixed-stream trap | Why it fails | Required action |
|---|---|---|
| Unknown acid rated by analogy | No listed row matches the chemistry | Compatibility test or written review |
| Blend judged on one component | Mixture behaviour differs from parts | Evaluate full composition with concentration/heat |
| Better component rating carried over | Ratings cannot be combined | Assess the stream on its own data |
| Vapour phase ignored | Atmospheric contact attacks the face continuously | Record vapour chemistry and exposure duration |
Mixtures can behave differently from single acids; an unlisted blend must be evaluated on its own composition, not by the weakest listed component.
4. Review fields before an order can proceed
For an unlisted medium, capture mixture composition, strength range, temperature range, vapour phase and contact mode, and flag cyclic or mixed exposure for review. Keep the tested basis tied to the resin family ordered; a report for another laminate does not transfer.
The missing evidence — compatibility data or a test plan, plus mixture proportions, vapour phase and strength range — must close with factory or engineering. Until a matched resin is returned, the panel stays a held preliminary selection.
5. Frequently Asked Questions
Which resin suits unlisted or custom mixtures exposure on FRP grating?
No resin family is confirmed for unlisted or custom mixtures from the published basis. The medium is unlisted, so an A/B/C grade cannot be assigned; a documented compatibility check or test covering media outside the reference chemical table precedes specification. A medium absent from the table must not be rated by analogy; treat it as test-required and obtain a written confirmation before specification.
Is unlisted or custom mixtures covered by the reference compatibility chart?
No. unlisted or custom mixtures is absent from the reference compatibility listing. Treat the service as test-required and close the missing evidence by factory or engineering review before ordering.
Does this resin choice certify food-safe or drinking-water use?
No. Food-contact and drinking-water compliance are not established from the resistance chart. Where the project requires such approval, obtain the matched compliance document and verify it against the destination regulation before ordering.
What changes the resistance rating besides the resin family?
Concentration, heat and contact type all move the rating. At higher temperature or concentration the grade drops one step; immersion is stricter than splash or intermittent wetting.
What must be confirmed before an order for this service?
Provide the exact medium, min/max concentration, min/max temperature and contact type. Critical, hot, concentrated or unlisted exposure needs a written factory confirmation or project-specific test; combined duty stays on technical review.
Reference PDFs: resin-selection-guide.pdf · chemical-resistance-table.pdf