The factory load table gives indicative allowable uniform loads (UDL) at the L/200 deflection limit for a simply supported single span, for preliminary sizing only. To select a build-up, compare your design UDL at your actual support span against the table; choose the first section whose value at that span meets or exceeds your design load. Deflection sag is recomputed as δ = span / deflection-limit.
- Table values are uniform loads only — not point, wheel, concentrated or cantilever capacities.
- At a tighter limit such as L/360, usable load drops; recalculate with the engineer's specified limit.
- Point loads, wheel loads, cantilevers, impact, fatigue and temperature derating require a separate project-specific engineering review.
How this article differs: this page works through numbered selection examples, panel weight/count math and unit conversions from the published table. It complements the interactive load-span calculator and does not restate point-load ratings, safety-factor tables or cantilever cases, which are out of scope here.
What the Allowable Load Table Covers
The figures below are reproduced from the factory load table and technical data sheet. They are indicative allowable uniform loads for preliminary design; they do not replace a stamped project calculation, and final figures must be confirmed against the factory test report and order drawing.
| Build-up | 600 mm span | 900 mm span | 1200 mm span |
|---|---|---|---|
| Moulded 25 mm | 12.5 kN/m² | 6.0 kN/m² | 3.2 kN/m² |
| Moulded 38 mm | 25 kN/m² | 12 kN/m² | 6.5 kN/m² |
| Moulded 38 mm, 50×50 mesh | 22 kN/m² | 10 kN/m² | 5.5 kN/m² |
| Pultruded 38 mm | 35 kN/m² | 18 kN/m² | 9 kN/m² |
| Pultruded 50 mm | 48 kN/m² | 26 kN/m² | 14 kN/m² |
| Pultruded 65 mm (HD) | 62 kN/m² | 35 kN/m² | 20 kN/m² |
Basis: deflection limit L/200, simply supported single span. Source: frp-grating-load-table.pdf and frp-grp-grating-technical-data-sheet.pdf.
Worked Example 1 — Pedestrian Walkway, 900 mm Span
Design case: maintenance walkway, supports at 900 mm centre-to-centre, design UDL 10 kN/m², deflection limit L/200.
| Build-up | Table value at 900 mm | Versus 10 kN/m² | Decision |
|---|---|---|---|
| Moulded 25 mm | 6.0 kN/m² | 6.0 < 10 | Not adequate |
| Moulded 38 mm | 12 kN/m² | 12 ≥ 10 | Adequate on UDL |
| Pultruded 38 mm | 18 kN/m² | 18 ≥ 10 | Adequate, larger reserve |
Recomputable check: the 12 kN/m² moulded 38 mm value is read directly from the table at the 900 mm column. Any safety margin beyond the table value is set by the project engineer, not by this sheet.
Worked Example 2 — Service Platform, 1200 mm Span
Design case: inspection platform, 1200 mm span, design UDL 6 kN/m², L/200.
| Build-up | Table value at 1200 mm | Versus 6 kN/m² | Decision |
|---|---|---|---|
| Moulded 25 mm | 3.2 kN/m² | 3.2 < 6 | Not adequate |
| Moulded 38 mm | 6.5 kN/m² | 6.5 ≥ 6 | Marginal on UDL; confirm reserve |
| Pultruded 38 mm | 9 kN/m² | 9 ≥ 6 | Adequate with reserve |
Where the table value is only slightly above the design load, move to the deeper or pultruded section rather than relying on a thin margin. Long spans and any rolling load should be reviewed against the engineer's deflection limit.
Deflection Sag Check (L/200 vs L/360)
Sag is calculated as δ = L / limit. For a 900 mm span: L/200 = 900/200 = 4.5 mm; L/360 = 900/360 = 2.5 mm. The L/360 sag is about 0.56 of the L/200 sag.
| Span L | L/200 deflection | L/360 deflection | Ratio L/360 ÷ L/200 |
|---|---|---|---|
| 600 mm | 3.0 mm | 1.67 mm | 0.56 |
| 900 mm | 4.5 mm | 2.5 mm | 0.56 |
| 1200 mm | 6.0 mm | 3.33 mm | 0.56 |
Source: load-conversion-tables.pdf. If your project specification uses L/360, the usable load at that limit is lower than the L/200 table; request a recalculation rather than reading the L/200 figure directly.
Panel Area, Weight and Count
Standard panel is 1220 × 3660 mm. Panel area = 1.220 × 3.660 = 4.465 m². Using the moulded 38 mm weight of 19.5 kg/m², one full panel weighs about 19.5 × 4.465 ≈ 87.1 kg, consistent with the roughly 87 kg reference in the load table.
| Quantity check | Calculation | Result |
|---|---|---|
| Panel area | 1.220 m × 3.660 m | 4.465 m² |
| Full 38 mm panel weight | 19.5 kg/m² × 4.465 m² | ≈ 87.1 kg |
| Deck 6.0 m × 2.44 m | 14.64 m² ÷ 4.465 m² | 4 panels by area (verify cutting waste) |
| Deck weight estimate | 14.64 m² × 19.5 kg/m² | ≈ 285 kg |
Cutting pattern, offcuts and opening cut-outs are checked in the panel layout calculator; the area method above is a preliminary estimate only.
Unit Conversion Factors
| From | To | Multiply by | Reverse factor |
|---|---|---|---|
| kg/m² | lb/ft² | 0.2048 | 4.882 |
| kN/m² | lb/ft² | 20.9 | 0.0478 |
| kN/m² | kgf/m² | 101.97 | 0.00981 |
| mm | inch | 0.03937 | 25.4 |
| m | foot | 3.281 | 0.3048 |
Example: 12 kN/m² × 20.9 ≈ 251 lb/ft², matching the conversion table.
Inputs to Your RFQ
To return a build-up recommendation and a matched load table, send: application, support span, design UDL, deflection limit, resin environment, surface finish, panel count estimate, and any opening cut-outs. Use the specification builder, the span-load calculator and the weight calculator to assemble the brief; browse the spec series for typical sections.
Reference PDFs: load table · technical data sheet · load conversion tables · engineer & designer guidelines.
Frequently Asked Questions
What deflection limit do your load tables use by default?
The factory allowable load table is calculated at L/200 for a simply supported single span. If your specification requires L/250 or L/360, request a recalculation; the usable load at a tighter limit is lower.
Can I read a wheel load or pallet-jack rating from this table?
No. The table lists uniform loads only. Wheel, point, concentrated and cantilever cases need a separate project-specific engineering review and matched evidence; no wheel or point load figure is claimed on this page.
How do I estimate how many panels my deck needs?
Divide deck area by the standard panel area of 4.465 m² (1.220 × 3.660 m), then verify the cutting pattern and offcuts in the panel layout calculator. The area method is preliminary and does not account for cut-outs.
What does the 38 mm moulded panel weigh?
Indicative weight is 19.5 kg/m²; a full 1220 × 3660 mm panel weighs about 87 kg. Confirm weight for the exact mesh and resin on the order drawing.
What if my span is longer than 1200 mm?
The table covers 600, 900 and 1200 mm spans. Longer spans, multi-span layouts and any cantilevered edge must be checked by the project engineer against a matched load report.
What are the MOQ and lead time?
MOQ is 10 m². Standard production is 15–25 working days after drawing approval; overall 12–36 working days overall. Indicative pricing is USD 15–95/m², depending on resin, thickness, surface, quantity and processing.
Send span, design load, deflection limit, resin and medium. We return a build-up recommendation and the matched load table.