FRP Grating UDL Span Selection: Worked Load-Table Examples and Deflection Checks

Engineering Data
Direct Answer

The factory load table gives indicative allowable uniform loads (UDL) at the L/200 deflection limit for a simply supported single span, for preliminary sizing only. To select a build-up, compare your design UDL at your actual support span against the table; choose the first section whose value at that span meets or exceeds your design load. Deflection sag is recomputed as δ = span / deflection-limit.

  • Table values are uniform loads only — not point, wheel, concentrated or cantilever capacities.
  • At a tighter limit such as L/360, usable load drops; recalculate with the engineer's specified limit.
  • Point loads, wheel loads, cantilevers, impact, fatigue and temperature derating require a separate project-specific engineering review.

How this article differs: this page works through numbered selection examples, panel weight/count math and unit conversions from the published table. It complements the interactive load-span calculator and does not restate point-load ratings, safety-factor tables or cantilever cases, which are out of scope here.

What the Allowable Load Table Covers

The figures below are reproduced from the factory load table and technical data sheet. They are indicative allowable uniform loads for preliminary design; they do not replace a stamped project calculation, and final figures must be confirmed against the factory test report and order drawing.

Build-up600 mm span900 mm span1200 mm span
Moulded 25 mm12.5 kN/m²6.0 kN/m²3.2 kN/m²
Moulded 38 mm25 kN/m²12 kN/m²6.5 kN/m²
Moulded 38 mm, 50×50 mesh22 kN/m²10 kN/m²5.5 kN/m²
Pultruded 38 mm35 kN/m²18 kN/m²9 kN/m²
Pultruded 50 mm48 kN/m²26 kN/m²14 kN/m²
Pultruded 65 mm (HD)62 kN/m²35 kN/m²20 kN/m²

Basis: deflection limit L/200, simply supported single span. Source: frp-grating-load-table.pdf and frp-grp-grating-technical-data-sheet.pdf.

Worked Example 1 — Pedestrian Walkway, 900 mm Span

Design case: maintenance walkway, supports at 900 mm centre-to-centre, design UDL 10 kN/m², deflection limit L/200.

Build-upTable value at 900 mmVersus 10 kN/m²Decision
Moulded 25 mm6.0 kN/m²6.0 < 10Not adequate
Moulded 38 mm12 kN/m²12 ≥ 10Adequate on UDL
Pultruded 38 mm18 kN/m²18 ≥ 10Adequate, larger reserve

Recomputable check: the 12 kN/m² moulded 38 mm value is read directly from the table at the 900 mm column. Any safety margin beyond the table value is set by the project engineer, not by this sheet.

Worked Example 2 — Service Platform, 1200 mm Span

Design case: inspection platform, 1200 mm span, design UDL 6 kN/m², L/200.

Build-upTable value at 1200 mmVersus 6 kN/m²Decision
Moulded 25 mm3.2 kN/m²3.2 < 6Not adequate
Moulded 38 mm6.5 kN/m²6.5 ≥ 6Marginal on UDL; confirm reserve
Pultruded 38 mm9 kN/m²9 ≥ 6Adequate with reserve

Where the table value is only slightly above the design load, move to the deeper or pultruded section rather than relying on a thin margin. Long spans and any rolling load should be reviewed against the engineer's deflection limit.

Deflection Sag Check (L/200 vs L/360)

Sag is calculated as δ = L / limit. For a 900 mm span: L/200 = 900/200 = 4.5 mm; L/360 = 900/360 = 2.5 mm. The L/360 sag is about 0.56 of the L/200 sag.

Span LL/200 deflectionL/360 deflectionRatio L/360 ÷ L/200
600 mm3.0 mm1.67 mm0.56
900 mm4.5 mm2.5 mm0.56
1200 mm6.0 mm3.33 mm0.56

Source: load-conversion-tables.pdf. If your project specification uses L/360, the usable load at that limit is lower than the L/200 table; request a recalculation rather than reading the L/200 figure directly.

Panel Area, Weight and Count

Standard panel is 1220 × 3660 mm. Panel area = 1.220 × 3.660 = 4.465 m². Using the moulded 38 mm weight of 19.5 kg/m², one full panel weighs about 19.5 × 4.465 ≈ 87.1 kg, consistent with the roughly 87 kg reference in the load table.

Quantity checkCalculationResult
Panel area1.220 m × 3.660 m4.465 m²
Full 38 mm panel weight19.5 kg/m² × 4.465 m²≈ 87.1 kg
Deck 6.0 m × 2.44 m14.64 m² ÷ 4.465 m²4 panels by area (verify cutting waste)
Deck weight estimate14.64 m² × 19.5 kg/m²≈ 285 kg

Cutting pattern, offcuts and opening cut-outs are checked in the panel layout calculator; the area method above is a preliminary estimate only.

Unit Conversion Factors

FromToMultiply byReverse factor
kg/m²lb/ft²0.20484.882
kN/m²lb/ft²20.90.0478
kN/m²kgf/m²101.970.00981
mminch0.0393725.4
mfoot3.2810.3048

Example: 12 kN/m² × 20.9 ≈ 251 lb/ft², matching the conversion table.

Boundaries this table cannot settle. The load table does not provide point loads, wheel loads, concentrated loads, cantilever capacity, continuous multi-span redistribution, impact resistance, fatigue life, or temperature-based strength derating. Any of these cases — and any rolling equipment, vehicle or handcart deck — requires a separate structural engineering review and, where available, a matched test report. Do not read a UDL figure as a wheel or point rating.

Inputs to Your RFQ

To return a build-up recommendation and a matched load table, send: application, support span, design UDL, deflection limit, resin environment, surface finish, panel count estimate, and any opening cut-outs. Use the specification builder, the span-load calculator and the weight calculator to assemble the brief; browse the spec series for typical sections.

Reference PDFs: load table · technical data sheet · load conversion tables · engineer & designer guidelines.

Frequently Asked Questions

What deflection limit do your load tables use by default?

The factory allowable load table is calculated at L/200 for a simply supported single span. If your specification requires L/250 or L/360, request a recalculation; the usable load at a tighter limit is lower.

Can I read a wheel load or pallet-jack rating from this table?

No. The table lists uniform loads only. Wheel, point, concentrated and cantilever cases need a separate project-specific engineering review and matched evidence; no wheel or point load figure is claimed on this page.

How do I estimate how many panels my deck needs?

Divide deck area by the standard panel area of 4.465 m² (1.220 × 3.660 m), then verify the cutting pattern and offcuts in the panel layout calculator. The area method is preliminary and does not account for cut-outs.

What does the 38 mm moulded panel weigh?

Indicative weight is 19.5 kg/m²; a full 1220 × 3660 mm panel weighs about 87 kg. Confirm weight for the exact mesh and resin on the order drawing.

What if my span is longer than 1200 mm?

The table covers 600, 900 and 1200 mm spans. Longer spans, multi-span layouts and any cantilevered edge must be checked by the project engineer against a matched load report.

What are the MOQ and lead time?

MOQ is 10 m². Standard production is 15–25 working days after drawing approval; overall 12–36 working days overall. Indicative pricing is USD 15–95/m², depending on resin, thickness, surface, quantity and processing.

Need a panel recommendation for your span and load?

Send span, design load, deflection limit, resin and medium. We return a build-up recommendation and the matched load table.

Published: 2026-11-20 | Category: Engineering Data | Author: FRP Grating Technical Team