FRP Grating Purchase Specification & Evidence Package: Standards and Fire Documents to Request

Procurement & Compliance
Direct Answer

A purchase specification should fix the build-up, resin, surface, panel size, span and design load, deflection limit, fixing arrangement, QC checks and documentation package. Standards such as EN ISO 14122, OSHA 1910, DIN 24537, RAL-GZ 638 and ASTM F3059 are reference documents; compliance is verified against the project's required standard and the matched report.

  • Fire performance is evidenced by the report matching the exact resin system supplied. This page does not state an E-84 or EN 13501 class for our panels.
  • Request the report number, test date, product description and issuing lab for every claimed property; do not compare labels across different standards.
  • Additional destination certifications and food-contact compliance are not claimed as held; confirm applicability before tender.

How this article differs: this page assembles the purchase specification and evidence-request package for buyers and engineers. It does not explain E-84 or EN 13501 rating scales, and it does not assign any fire class to our panels; rating terminology is left to the dedicated standards articles, and any class must come from the matched report.

What a Purchase Specification Should Fix

Two RFQs can quote the same "38 mm grating" and receive different products. The clauses below remove that ambiguity and tie the quote to a verifiable build-up.

ClauseWhat to specifyLinks to
Build-upMolded or pultruded; bar/profile depth; meshSpec series
ResinOrtho / Iso / VE / Epoxy / Phenolic, matched to mediumResin brief article
SurfaceSmooth, concave, grit top or covered solidProduct range
Panel sizeStandard 1220 × 3660 mm or cut-to-sizeOrder drawing
Structural dutySupport span, design UDL, deflection limitLoad-table article
FixingsClip family and finish; layout per support drawingClips product
QCBarcol hardness, dimensional check, inspection recordDocumentation package
DocumentationMatched load/deflection, resin confirmation, test reportsRFQ evidence request

Standards References and How to Use Them

The baseline site maintains reference pages for the documents below. Each describes a safety, access or testing context; the governing requirement for a project is the standard named in that project's specification, and the delivered product must be checked against the matched report.

ReferenceContextBaseline page
EN ISO 14122Permanent access machinery, walkway and guarding requirementsEN ISO 14122
OSHA 1910General industry guarding, railing and walking-working surfacesOSHA 1910
DIN 24537Steel/composite grating platform and walkway referenceDIN 24537
RAL-GZ 638Quality assurance community reference for grating productsRAL-GZ 638
ASTM F3059Pedestrian surface characteristics for FRP gratingASTM F3059 article

Documentation Package to Request

DocumentWhat it should showStatus on request
Inspection / material recordBatch traceability, resin, glass content, dimensionsAvailable on request
Barcol hardness checkBarcol 40 or above on a sound panelQC record per batch
Load / deflection reportMatched to the stated build-up, span and limitPer project build-up
Resin / chemical confirmationWritten confirmation for the stated mediumFor critical service
Fire reportMatched to the exact resin system suppliedSee evidence procedure below

We hold an ISO 9001 quality management system. Certificate numbers, issue dates and validity are not reproduced on this page; verify them against the matched document provided with the order. Third-party load and material reports are available on request.

Fire Performance: How to Check the Matched Report

Fire performance belongs to the specific resin system, not to "FRP grating" as a category. Use the following procedure when fire evidence matters; do not rely on a class label quoted generically.

  1. Identify the resin system on the purchase order (e.g., fire-retardant polyester, vinyl ester, phenolic).
  2. Request the fire test report that matches that exact resin and product description.
  3. Check the report standard against the destination requirement — for example ASTM E-84, EN 13501-1, or IMO FTP Code where applicable — these are different scales and cannot be compared directly.
  4. Confirm the test date, product description and issuing laboratory on the report itself.
  5. Verify the report applies to the panel section and surface being supplied, not a related grade.
Compliance boundary. This page does not claim that our panels carry a specific ASTM E-84 flame-spread class or an EN 13501 classification. Any fire class quoted for a project must come from the matched report for the supplied resin. Fire terminology is explained in the related standards articles below.

Market and Compliance Boundaries

Before tendering into a regulated destination, confirm which market certifications apply. The following are not claimed as held on this site: CSA / ULC (Canada), GOST / EAEU / EAC (Eurasian Union), SASO / SABER (Saudi Arabia), TISI (Thailand), INMETRO (Brazil), PN (Poland), NBN / NEN (Belgium/Netherlands), NORSOK (Norway offshore), LVS (Latvia). Food-contact and drinking-water compliance are likewise not claimed unless separate evidence is provided and verified.

Commercial Terms

ItemTerm
Minimum order (MOQ)10 m²
Standard production15–25 working days after drawing approval
Overall lead time12–36 working days overall
Indicative priceUSD 15–95/m² (resin, thickness, surface, quantity and processing dependent)
Manufacturing historyFounded 2004; 200+ employees; 20,000+ m² plant
Export reach45+ countries; 541+ customer reviews, 4.9/5 average rating

Assemble the RFQ

Enter build-up, resin, medium, span, load, deflection limit, surface and destination in the specification builder; review sections in the spec series and standards pages above, then send the package through the contact / RFQ channel.

Frequently Asked Questions

Do these articles state an ASTM E-84 or EN 13501 class for your grating?

No. This page does not assign a fire class to our panels. Fire performance is checked from the test report that matches the exact resin system supplied; verify the standard, product description, test date and lab on that report.

What documents should I request with the order?

Request the inspection/material record, Barcol hardness check, a load/deflection report matched to the stated build-up, written resin confirmation for critical service, and the fire report matching the supplied resin where fire evidence is required.

Which standards apply to my walkway?

The governing standard is the one named in your project specification. Reference pages cover EN ISO 14122, OSHA 1910, DIN 24537, RAL-GZ 638 and ASTM F3059; compliance must be verified against the matched report for the delivered product.

Do you hold CSA, EAC, SASO, INMETRO or other destination certificates?

These market certifications are not claimed as held on this site. Confirm the destination requirements before tender and request specific evidence where it applies.

Is the grating food-contact or drinking-water safe?

Food-contact and drinking-water compliance are not claimed from this site. If the application requires such approval, request the specific compliance evidence and verify it against the destination regulation.

What are the MOQ, lead time and price range?

MOQ is 10 m²; standard production is 15–25 working days after drawing approval, overall 12–36 working days overall. Indicative pricing is USD 15–95/m², varying with resin, thickness, surface, quantity and processing work.

Need a panel recommendation for your span and load?

Send span, design load, deflection limit, resin and medium. We return a build-up recommendation and the matched load table.

Published: 2026-11-20 | Category: Procurement & Compliance | Author: FRP Grating Technical Team