recognizing long-span or heavy-platform decks where continuous deep bar profiles are considered over interwoven mesh panels
- Review whether the planned span exceeds practical molded coverage.
- Consider I-bar for heavier platforms and long continuous runs.
- Compare T-bar for walkways against I-bar for stiffer long-span duty.
1. Scope and Engineering Context
A molded mesh panel spreads pedestrian load across an interwoven face; a pultruded I-bar carries bending along a continuous deep member. When a deck reaches a long span or a heavier working platform, that continuous bar often answers better than a mesh panel, and the switch is made from span and duty rather than surface look.
The review first asks whether the planned span sits beyond practical molded coverage, then compares T-bar walkway sections against deeper I-bar platform sections, matching profile depth to the support spacing and the contract deflection limit.
- pultruded I-bar. A deep pultruded profile whose continuous bar carries bending between supports, used for longer spans and heavier platforms.
- long span. The extended distance between main supports that pushes beyond what a moderate molded panel comfortably covers.
- heavy platform. A standing working deck that may hold tools, staged equipment or denser traffic, heavier than a passing walkway.
- continuous bar. The unbroken bar running from one support to the other, providing the spanning stiffness in an I-bar deck.
- profile depth. The chosen bar depth, matched to spacing, duty and the required sag limit rather than picked by appearance.
2. Worked Example and Site Checklist
Compare the verified I-bar rows across spacing. The 38 mm series allows 35, 18 and 9 kN/m² at 600, 900 and 1200 mm; the 50 mm reaches 48, 26 and 14; the 65 HD reaches 62, 35 and 20. Unit weights for the I-bar family run roughly 10.5 kg/m at 25 mm, 12.5–14.5 at 38 mm, 16.5–19 at 50 mm and 23–26 kg/m at 76 mm, per the verified series.
Where a long platform at 1200 mm carries a heavier duty, the deeper I-bar row is the relevant comparison; a molded panel continued onto that span is read against its own lower row, not the I-bar figures. Any special heavy or rolling duty shown in the brief must be confirmed by an engineer against a matched report.
| Check on site | What to record | Why it matters |
|---|---|---|
| Check span against molded coverage | Record whether the spacing exceeds the practical molded range | The long-span case is what moves the review toward continuous bars. |
| Assess platform weight and tools | Note staged equipment and standing work on the deck | Heavy duty leans on deeper I-bar rather than a mesh panel. |
| Compare T-bar and I-bar options | Separate moderate walkway duty from stiffer long-span duty | T-bar suits walkways; I-bar serves heavier long platforms. |
| Match depth to spacing and limit | Copy the deflection limit and selected bar depth | Profile depth must satisfy both span and the contract sag figure. |
| Flag heavy or rolling duty | Mark any wheels, equipment or impact in the brief | Special duty needs engineer confirmation before the section is fixed. |
| Item | Verified figure / note |
|---|---|
| Pultruded I-bar 38 mm | 35 / 18 / 9 kN/m² at 600/900/1200 mm |
| Pultruded I-bar 50 mm | 48 / 26 / 14 kN/m² |
| Pultruded I-bar 65 HD | 62 / 35 / 20 kN/m² |
| I-bar unit weight range | 10.5 to 26 kg/m by depth |
3. Failure Modes and Cautions
A recurring over-reach keeps a molded mesh panel on a long platform it was not oriented for. Once the span passes molded coverage, the mesh sags earlier than the rated figure suggests; the closer-spacing rating cannot rescue a deck continued over a wider gap.
The reverse mistake fits an I-bar to a short, light walkway. The deep bar adds mass, framing load and cost that the duty does not justify; a heavier profile on a moderate route is over-specification, not extra safety.
- Compare allowable load at the actual span; do not judge profile strength by bar depth alone.
- State span, design load, deflection limit, equipment or rolling duty and environment in the RFQ.
- Keep the selected I-bar depth and its bearing conditions in the record for later review.
4. Boundary: When This Does Not Apply
This family discussion covers preliminary long-span selection under uniform load. It does not settle concentrated or point loads, wheeled rolling duty, cantilever projections, impact, fatigue life, snow load, wind-uplift fixing, seismic anchors or temperature derating; each goes to an independent structural assessment.
An I-bar rating from one span or duty must not be extended to another without re-checking the series. Where the deck carries staged machinery or penetrations, the load case is reviewed separately; profile choice does not close an opening-reinforcement or edge-detail question.
5. Frequently Asked Questions
What duty suits a pultruded I-bar?
I-bar profiles are used for longer spans and heavier platforms where continuous deep bars provide the needed stiffness; T-bar remains common for moderate walkway duty.
How deep can an I-bar section go?
The verified I-bar series covers 25, 38, 50 and 76 mm depths with published unit weight ranges; choose depth against span and duty from the table.
Is I-bar stronger than molded for the same depth?
Profile types differ in how they carry load; compare allowable load at the actual span rather than judging strength by depth alone.
When should molded still be preferred?
For moderate spans, general walkways and where mesh spread or surface pattern matters, molded panels often remain appropriate.
What does the RFQ need for an I-bar proposal?
State span, design load, deflection limit, equipment or rolling duty and environment so the I-bar depth can be checked against the profile series.