76 mm I-Bar Pultruded FRP Grating
The deepest standard pultruded section: four and a half metres and beyond, where a steel deck would need extra beams or a crane.
Technical specifications
| Type | Pultruded FRP grating, I-bar section, extra deep bar |
|---|---|
| Bearing bar depth | 76 mm (3 in) |
| Section | I profile with top and bottom flange |
| Bar pitch | 38 mm standard |
| Open area | about 50% (clear 19 mm) or about 60% (clear 23 mm) |
| Unit weight | about 26 kg/m² at 50% open; about 23 kg/m² at 60% open |
| Standard panel | 1220 x 3660 mm; 6000 mm on request; cut to size |
| Resin systems | Isophthalic polyester; vinyl ester; phenolic |
| Surface | Concave or grit; grit recommended on any sloped deck |
| Fixing | Heavy-duty saddle, SS316 bolts, end and intermediate fixings per load table |
Load and span guidance
| Support span | Indicative UDL, 50% open | Indicative UDL, 60% open | Deflection basis |
|---|---|---|---|
| 3.0 m | about 780 kg/m² | about 680 kg/m² | L/200 |
| 3.5 m | about 565 kg/m² | about 490 kg/m² | L/200 |
| 4.0 m | about 425 kg/m² | about 370 kg/m² | L/200 |
| 4.5 m | about 330 kg/m² | about 285 kg/m² | L/200 |
Indicative values for a single simply supported span under uniform load. At this depth the deck is normally used where the span cannot be reduced, and the deflection limit is the design driver. Certified values, including wind and snow combinations, are supplied with the quotation.
Sizing a very long span honestly
At 76 mm the section is stiff enough for four and a half metres at foot-traffic load, and it is the point at which a pultruded deck starts to compete directly with a steel grating on span rather than only on corrosion. It is also heavy at 23 to 26 kg/m², so the conversation moves to how the panel is lifted and how the supports are fixed rather than only to load capacity.
We do not recommend this section for spans beyond about five metres without an engineered check, and we will not present a five-metre deck as routine. Where the geometry really demands it, an intermediate bearer or a trussed support is usually cheaper and more honest than a deeper composite bar, and we say so before the quotation is issued rather than after the deck has been ordered.
Where it fits
- Long quay and jetty walkways between mooring points
- Cable and pipe bridges crossing wide service corridors
- Cooling tower and chimney access decks
- Large roof spans on industrial buildings with limited supports
- Replacement of long steel grating runs in corrosive service
A 76 mm panel of 6 m weighs around 190 kg, so mechanical lifting with spreader beams is required. The bearers should be checked for level and the panels laid with a small expansion gap at each end of a long run.