50 mm I-Bar Pultruded FRP Grating
A deep I-section for three and a half to four metre spans, where both stiffness and bar stability have to be right.
Technical specifications
| Type | Pultruded FRP grating, I-bar section, deep bar |
|---|---|
| Bearing bar depth | 50 mm (2 in) |
| Section | I profile with top and bottom flange |
| Bar pitch | 38 mm standard |
| Open area | about 40% (clear 15 mm) or about 50% (clear 19 mm) |
| Unit weight | about 19 kg/m² at 40% open; about 16.5 kg/m² at 50% open |
| Standard panel | 1220 x 3660 mm, cut to size; up to 6000 mm on request |
| Resin systems | Isophthalic polyester; vinyl ester; phenolic for offshore and fire-critical decks |
| Surface | Concave, grit, or smooth; grit standard on ramps |
| Fixing | Heavy-duty saddle and clip, SS316 bolts, spaced per load table |
Load and span guidance
| Support span | Indicative UDL, 40% open | Indicative UDL, 50% open | Deflection basis |
|---|---|---|---|
| 2.5 m | about 700 kg/m² | about 610 kg/m² | L/200 |
| 3.0 m | about 475 kg/m² | about 410 kg/m² | L/200 |
| 3.5 m | about 340 kg/m² | about 295 kg/m² | L/200 |
| 4.0 m | about 250 kg/m² | about 215 kg/m² | L/200 |
Indicative values for a single simply supported span under uniform load. At this depth the deck often replaces a steel grating of similar capacity at about one third of the weight, which is the reason it is chosen for roof and offshore structures where lifting capacity is fixed.
Long span without a mid bearer
A 50 mm I-bar deck reaches four metres on foot traffic, which is the point at which most clients would otherwise be adding a bearer, a beam and a crane lift to the programme. The section also keeps its shape under the concentrated loads that long-span decks attract, because a long panel deflects more and any tendency of the bar to twist shows up sooner than on a short span.
Weight is the other argument. At 19 kg/m² the deck weighs about one third of an equivalent steel grating, and every kilogram removed from the top of a roof or a jetty reduces the load the structure below has to carry. On retrofit work that weight difference is often what allows the existing frame to be reused instead of replaced.
Where it fits
- Roof and cooling tower walkways with long unbraced spans
- Jetty and quay decks exposed to salt and wave spray
- Offshore modules and helideck access, phenolic resin
- Long pipe rack and cable bridge crossings
- Heavy-duty landings and maintenance platforms for plant access
Long panels need a spreader or two-person lift at mid-length; carrying a 6 m panel by its ends will bow it. Bearers must be flat and aligned within a few millimetres, and expansion gaps are left at abutments where the deck runs between structures.
