FRP Grating Specifications

50 mm I-Bar Pultruded FRP Grating

A deep I-section for three and a half to four metre spans, where both stiffness and bar stability have to be right.

Technical specifications

TypePultruded FRP grating, I-bar section, deep bar
Bearing bar depth50 mm (2 in)
SectionI profile with top and bottom flange
Bar pitch38 mm standard
Open areaabout 40% (clear 15 mm) or about 50% (clear 19 mm)
Unit weightabout 19 kg/m² at 40% open; about 16.5 kg/m² at 50% open
Standard panel1220 x 3660 mm, cut to size; up to 6000 mm on request
Resin systemsIsophthalic polyester; vinyl ester; phenolic for offshore and fire-critical decks
SurfaceConcave, grit, or smooth; grit standard on ramps
FixingHeavy-duty saddle and clip, SS316 bolts, spaced per load table

Load and span guidance

Support spanIndicative UDL, 40% openIndicative UDL, 50% openDeflection basis
2.5 mabout 700 kg/m²about 610 kg/m²L/200
3.0 mabout 475 kg/m²about 410 kg/m²L/200
3.5 mabout 340 kg/m²about 295 kg/m²L/200
4.0 mabout 250 kg/m²about 215 kg/m²L/200

Indicative values for a single simply supported span under uniform load. At this depth the deck often replaces a steel grating of similar capacity at about one third of the weight, which is the reason it is chosen for roof and offshore structures where lifting capacity is fixed.

Long span without a mid bearer

A 50 mm I-bar deck reaches four metres on foot traffic, which is the point at which most clients would otherwise be adding a bearer, a beam and a crane lift to the programme. The section also keeps its shape under the concentrated loads that long-span decks attract, because a long panel deflects more and any tendency of the bar to twist shows up sooner than on a short span.

Weight is the other argument. At 19 kg/m² the deck weighs about one third of an equivalent steel grating, and every kilogram removed from the top of a roof or a jetty reduces the load the structure below has to carry. On retrofit work that weight difference is often what allows the existing frame to be reused instead of replaced.

Where it fits

  • Roof and cooling tower walkways with long unbraced spans
  • Jetty and quay decks exposed to salt and wave spray
  • Offshore modules and helideck access, phenolic resin
  • Long pipe rack and cable bridge crossings
  • Heavy-duty landings and maintenance platforms for plant access

Long panels need a spreader or two-person lift at mid-length; carrying a 6 m panel by its ends will bow it. Bearers must be flat and aligned within a few millimetres, and expansion gaps are left at abutments where the deck runs between structures.

Related resources

FAQ

W
A
H
A
D
Y
I
Y
C
P
H
C

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to [email protected]. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: [email protected]