Mid-strength and concentrated sulfuric are highly aggressive and can release heat on dilution. The reference chart lists sulfuric at 10–50 % below 40 °C as C for ortho and iso, B for vinyl ester and epoxy; this row is a conservative basis, not a clearance for concentrated or hot service. Strong-acid duty should not be selected from the table alone and needs a written compatibility test or confirmation.
- Listed basis: sulfuric 10–50 % <40 °C — ortho C, iso C, VE B, epoxy B.
- Concentrated sulfuric releases heat and can attack the matrix; the upper band is treated as test-required.
- Heat release, fume and spill-containment design are part of the engineering review.
1. Why concentrated sulfuric sits beyond the chart
Strong sulfuric combines acidic attack with heat behaviour: as it dilutes it can release warmth that raises the panel's local temperature. The 10–50 % row gives a cautious reading — VE and epoxy B, iso and ortho C — but that premise does not describe a full-strength, hot or continuously immersed duty, which stays outside the table envelope.
In concentrated service the laminate face meets strong liquor, possible fume and residue that concentrates while drying. Where the matrix or an edge opens up, the acid can reach the fibres; such harsh contact should be settled by a specimen test or written confirmation rather than a family-level assumption.
| Service condition | Ortho | Iso | VE | Epoxy |
|---|---|---|---|---|
| Sulfuric 10–50 %, <40 °C | C | C | B | B |
2. Heat, fume and trapped liquor
Dilution heat raises the actual panel temperature apart from the listed 40 °C premise. Fume and mist can reach the laminate continuously, and residue after a spill concentrates acid on the skin; these conditions exceed a mid-strength splash reading and belong in the engineering review.
Drainage, bunding and residue washdown govern how long the panel meets the acid. A sump or bund that traps strong liquor keeps contact continuous; that mode is stricter than splash and needs its own compatibility basis before the grating is specified.
3. Reasons a table grade is insufficient
Choosing a resin for concentrated sulfuric from the listed mid-strength row alone is a clear miss. The B reading for VE or epoxy does not extend to full-strength, hot or soaking duty; assuming otherwise leaves the panel without a tested basis. Treating iso or ortho C as workable for strong acid is another trap, which the reference marks test required or not recommended.
Extending the VE B rating across exotherm, fume or immersion is equally unsupported. Where the stream concentrates, heats or stays pooled, the panel routes to engineering compatibility review; a spill that proves harsher than planned should not rely on surface repair, and that panel must be pulled from the duty for re-evaluation.
| Aggressive case | Review item | Evidence to obtain |
|---|---|---|
| Full-strength or hot liquor | Exotherm and concentration above basis | Specimen test; written confirmation |
| Trapped / pooled acid | Contact stricter than splash | Immersion-specific review |
| Fume and mist on the face | Continuous vapour contact | Vapour-phase compatibility record |
| Mixed acid effluent | Blend not covered by one rating | Full-stream composition data |
4. Information needed for the strong-acid review
Before a concentrated-sulfuric grating is ordered, write down the actual strength, expected temperature including dilution warmth, fume presence, and whether contact runs as immersion, splash or spill trap. Note bunding and drainage, since trapped liquor changes the duty.
The still-missing basis — a specimen test or written confirmation for concentrated acid, plus exotherm, fume and containment review — must be settled by the factory or engineering team. Until that test exists, the resin choice stays preliminary.
5. Frequently Asked Questions
Which resin suits concentrated sulfuric acid exposure on FRP grating?
The family is set by concentrated sulfuric acid, concentration, heat and contact type. The reference chart lists this medium within its stated envelope; those ratings apply only to the stated conditions. Concentrated sulfuric is highly aggressive and can release heat on dilution; do not select a resin from the table alone for this service.
Is concentrated sulfuric acid covered by the reference compatibility chart?
Yes, within the listed concentration and temperature envelope. Anything outside the listed conditions moves the grade down and needs a documented review rather than a table read.
Does this resin choice certify food-safe or drinking-water use?
No. Food-contact and drinking-water compliance are not established from the resistance chart. Where the project requires such approval, obtain the matched compliance document and verify it against the destination regulation before ordering.
What changes the resistance rating besides the resin family?
Concentration, heat and contact type all move the rating. At higher temperature or concentration the grade drops one step; immersion is stricter than splash or intermittent wetting.
What must be confirmed before an order for this service?
Provide the exact medium, min/max concentration, min/max temperature and contact type. Critical, hot, concentrated or unlisted exposure needs a written factory confirmation or project-specific test; combined duty stays on technical review.
Put the agreed test basis and its stated limits in the order record, and attach them to the purchase order so the approved duty is not lost between inquiry and delivery.
Reference PDFs: chemical-resistance-table.pdf · resin-selection-guide.pdf