Nitric acid is an oxidising medium, harsher than an ordinary acid on the resin matrix. The reference chart lists nitric below 10 % and below 40 °C as C for ortho and iso, B for vinyl ester and epoxy. Even dilute service is rated conservatively; concentrated or hot contact sits outside the table envelope and needs a test or written review before selection.
- Listed basis: nitric <10 % <40 °C — ortho C, iso C, VE B, epoxy B.
- Oxidiser chemistry attacks the matrix beyond ordinary acid tolerance.
- Concentrated, hot or fume-heavy nitric service routes to engineering compatibility review.
1. Oxidation behaviour of nitric on the laminate
Nitric does more than supply acidic contact: it oxidises the polymer matrix, which can dull, embrittle or soften the resin face even at dilute strength. This oxidising load explains the conservative listed readings — ortho and iso C, VE and epoxy B at the 10 % / 40 °C basis — rather than the stronger readings seen for some non-oxidising acids.
Fibres behind the matrix stay protected while the oxidising face holds; once the resin loses resistance, the medium reaches the reinforcement sooner. Fume and mist around nitric processing settle continuously on the panel, adding an atmospheric load the liquid rating does not by itself cover.
| Oxidiser factor | Ortho | Iso | VE | Epoxy |
|---|---|---|---|---|
| Nitric <10 %, <40 °C | C | C | B | B |
2. The conservative oxidiser limit
The chart row covers nitric under 10 % and under 40 °C. VE and epoxy B describe splash and intermittent wetting at this band; it does not clear concentrated acid, hot liquor or continuous immersion. Above the listed strength or heat, the grade drops one step and a fresh compatibility check is required.
Oxidising residue can concentrate on the face as it dries, raising the local load beyond the dilute basis. A panel meeting nitric fume or repeated washdown should be assessed for that atmospheric exposure separately; the liquid row alone does not establish vapour compatibility.
3. Judgements that confuse nitric with other acids
Treating nitric like an ordinary non-oxidising acid and selecting a polyester on that basis is a typical miss. Ortho and iso read C for this oxidiser, so those matrices are not rated for the contact; the oxidation attack can embrittle the face ahead of a listed VE or epoxy panel. Extending the VE or epoxy B to concentrated or hot nitric, where the grade drops and the duty needs review, is another error.
Fume-heavy nitric service is a further exposure the conservative row does not settle. Continuous mist, hot liquor or soaking contact should not inherit an intermittent-wetting B; those modes need their own written basis. Mixed oxidising effluent also cannot be resolved from the nitric row alone.
| Nitric case | Why cautious | Basis to obtain |
|---|---|---|
| Polyester on oxidising acid | Ortho/iso read C for nitric | VE or epoxy per listed basis |
| Concentrated or hot stream | Grade drops above band | Engineering compatibility review |
| Continuous fume or mist | Atmospheric oxidation unassessed | Vapour-phase written confirmation |
| Prolonged immersion | Soaking outside splash basis | Separate immersion review |
4. Monitoring oxidiser signs and specification inputs
Watch nitric panels for embrittlement, dulling, soft patches and fume residue; bar stiffness, clip fit and cut seals are checked each pass. Oxidiser damage tends to show as surface change first, so log early marks for review.
Specifying details to send: the nitric strength range, temperature range and exposure as splash, fume or immersion. The oxidiser compatibility data for the proposed resin, plus any concentrated, hot or fume-heavy duty review, has to be confirmed in writing by the factory or engineering group.
5. Frequently Asked Questions
Which resin suits nitric acid exposure on FRP grating?
The family is set by nitric acid, concentration, heat and contact type. The reference chart lists this medium within its stated envelope; those ratings apply only to the stated conditions. Nitric acid oxidises the resin matrix; even dilute service is rated conservatively, and concentrated contact is outside the table envelope.
Is nitric acid covered by the reference compatibility chart?
Yes, within the listed concentration and temperature envelope. Anything outside the listed conditions moves the grade down and needs a documented review rather than a table read.
Does this resin choice certify food-safe or drinking-water use?
No. Food-contact and drinking-water compliance are not established from the resistance chart. Where the project requires such approval, obtain the matched compliance document and verify it against the destination regulation before ordering.
What changes the resistance rating besides the resin family?
Concentration, heat and contact type all move the rating. At higher temperature or concentration the grade drops one step; immersion is stricter than splash or intermittent wetting.
What must be confirmed before an order for this service?
Provide the exact medium, min/max concentration, min/max temperature and contact type. Critical, hot, concentrated or unlisted exposure needs a written factory confirmation or project-specific test; combined duty stays on technical review.
Keep a single written record of the nitric strength range, temperature, wetting mode and any cleaning chemicals used on the deck. Send that record with the inquiry, and re-check the chart row if the process later runs hotter or stronger; a recorded change is easier to review than an assumed one.
Reference PDFs: chemical-resistance-table.pdf · resin-selection-guide.pdf