Fatigue develops under repeated cycles of load rather than a single event, and a deck that carries frequent rolling equipment or dense traffic sits outside the static uniform-load comparison.
- Classify the duty as periodic, repeated or high-cycle before selecting the section.
- Recognize preliminary rows give no fatigue-life rating for cyclic traffic.
- Plan recurring inspection of bars, roving and fixings on repeated-duty decks.
1. Fatigue Is Cyclic, Not a One-Time Load
A static load check asks whether the panel resists one application of weight at a given span. Fatigue asks a different question: whether the bars, resin and fixings survive many repeated cycles of that load over the service life. Cracks, resin crazing or loosening fixings can appear after repetition even when a single loading looked acceptable.
Composite response to cyclic loading depends on the glass arrangement, resin condition, bar section and how the load is applied; it is not captured by an allowable uniform figure read from a row. A deck exposed to frequent carts, trolleys or dense maintenance traffic is a cyclic-duty case to flag for review.
- fatigue. progressive damage caused by repeated loading cycles rather than a single overload.
- cycle. one repetition of a load applied and removed from the deck.
- high-cycle duty. service with a large number of repeated load applications, such as regular rolling equipment.
- cyclic load. a force that recurs over time, distinct from a one-time static weight.
- inspection cadence. the scheduled frequency at which bars, roving and fixings are rechecked.
2. Classifying the Duty Cycle
A periodic maintenance walkway crossed occasionally by a small crew is a light cyclic condition. A route used regularly by technicians carrying tools approaches repeated duty. A platform or path serving frequent rolling carts, trolleys or loaded equipment is closer to high-cycle duty and warrants a structured review of the section and fixings.
The classification uses load magnitude, repetition frequency and the type of movement. Walking contacts, resting boxes and wheeled rollers behave differently under repetition; a brief that records only average headcount or a single uniform figure misses the cyclic character the deck actually sees.
| Duty class | Typical service | Review posture |
|---|---|---|
| Periodic | Occasional crew inspection route | Preliminary row check; routine inspection |
| Repeated | Regular tool-carrying maintenance traffic | Note frequency; inspect bars and fixings |
| High-cycle | Frequent carts, trolleys or rolling equipment | Engineered fatigue review; scheduled inspection |
3. What the Preliminary Rows Cannot Establish
The comparative rows in the grating data list indicative uniform static loads for a simply supported span. They do not provide a fatigue life, a cycle-count rating or an allowable repeated load for cyclic traffic. Reading a higher row as if it promised endurance under many repetitions is not a valid basis for selection.
Where high-cycle duty is critical, fatigue performance follows an assessment of the material system, section and load cycles, supported by relevant evidence rather than a catalogue figure. That assessment also considers how fixings and joints behave under repetition, since loosening at a fixing can itself become a fatigue issue.
- State traffic frequency, wheeled equipment and expected service life in the brief.
- Do not treat a static allowable as a repeated-load or fatigue rating.
- Route critical cyclic decks to engineering review before the section is finalized.
4. Inspection Focus for Repeated Duty
On decks with regular traffic, recurring checks concentrate on the bars and resin at high-frequency crossing points, the condition of any exposed roving, signs of resin crazing or cracking, and whether clips and bearing contact remain seated. Loose fixings or frayed edges are noted early and corrected before they propagate.
| Inspection point | Signs to record |
|---|---|
| Bars under frequent traffic | Cracks, permanent set, surface damage |
| Resin surface | Crazing, chalking, softening or wear |
| Exposed roving | Fraying, loose fiber at bars or edges |
| Fixings | Loose clips, shifted bearing, gaps at the seat |
The inspection interval for a repeated-duty deck follows the service intensity and any guidance from the engineered review. A walkway used lightly may share the standard recurrence schedule; a high-cycle equipment route is checked more often and its condition recorded for trend review.
5. Boundary: Engineered Fatigue Assessment
This note separates static selection from cyclic-duty review. It does not calculate fatigue life, cycle capacity, joint endurance or dynamic amplification, and it does not replace materials testing or a structural assessment for critical repeated load.
A section selected for periodic access should not be assumed to serve a frequent rolling route without re-checking the cyclic condition. Where traffic frequency or equipment weight increases after installation, the original fatigue basis is reviewed again against the new duty.
6. Frequently Asked Questions
Does the grating load table give a fatigue life?
No. The rows are indicative static uniform loads; fatigue life and repeated-cycle ratings require a separate engineered assessment of the material, section and cycles.
What decks count as high-cycle duty?
Platforms or paths serving frequent carts, trolleys or rolling equipment, and dense recurring maintenance traffic, are cyclic-duty cases to review rather than read from the walking row.
How is repeated traffic inspected?
Check bars, resin, exposed roving and fixings at high-frequency points for cracks, crazing, fraying or looseness, on a schedule matched to the service intensity.
Does a deeper bar improve fatigue resistance?
Bar depth affects stiffness and local demand, but fatigue performance depends on the full material system under cyclic load; it is not established by the section depth alone.
What should the fatigue brief include?
Traffic frequency, load magnitude, any wheeled equipment, contact type and expected service life, so the cyclic duty can be classified and routed to review.