A Phenolic Grating Walkway for an Offshore Module
Offshore is the case where the documents decide the order before the price does. Phenolic resin for smoke, ASTM F3059 for the product, and a fixing schedule that survives salt and vibration.
An application case rather than a client reference: it describes how a walkway for offshore service is specified from the documentation requirement backwards. Client names and site photographs are released only with the client agreement.
Why offshore starts with documents
An offshore buyer does not ask for a price first. The enquiry opens with the classification society, the fire division requirement, the smoke and toxicity requirement, and the document package that has to be submitted. A quotation that arrives without knowing those is a quotation that will be re-issued.
That is why the deck specification here is written backwards from the document list: what has to be submitted decides which resin and which product assessment are acceptable.
The deck as specified
- Panel: phenolic molded grating, low smoke, grit surface for wet and oily walking conditions
- Product evidence: Intertek report to ASTM F3059, plus the ABS Product Design Assessment where the classification society asks for one
- Bearer: pultruded profile, phenolic where the division requirement extends to the frame
- Fixings: SS316 clips and bolts, isolated from dissimilar metals
- Handrail: round and square tube, with the geometry stated to the applicable standard
- Packing: sea freight packing with the document pack inside the crate
Three details that get missed onshore
First, the product assessment has a validity window. A PDA issued in 2017 and valid to 2022 is a historical document, and a buyer who needs current evidence should ask for the current issue rather than accept an expired one. We state the date and the window on the certificate page rather than presenting an old document as current.
Second, uplift. An offshore walkway sees wind and green water, and a panel fixed only at its edges will lift. The saddle clip and the corner fixings exist for this case.
Third, the bearer material. A phenolic panel on a polyester frame has one rated component. Where the division requirement applies to the structure, the frame is specified to the same resin.
What to send with an enquiry
Send the fire division requirement, the smoke and toxicity requirement, the classification society, the span and the load. With those five the quotation comes back with the right resin, the right product evidence and the right document list, instead of a price for the wrong deck.
Related pages
- Certifications and test reports
- Laboratory and test capability
- Phenolic grating
- FRP grating in a hydrocarbon fire
- Offshore and marine grating
- Pultruded profiles