In-House Laboratory and Test Capability
Which checks happen inside the plant, which go to a third-party laboratory, and what the buyer receives as evidence for each.
The checks that happen inside the plant
Four checks are done in house on every order: incoming resin documentation, dimensional inspection, cure and surface assessment, and a load or deflection check where the order calls for it. Each is recorded against the batch, not against the day.
Recording against the batch is what makes a complaint traceable. If a panel is soft or a pitch has drifted, the batch record shows which resin lot and which production run it came from.
| Check | Method |
|---|---|
| Resin documentation | Batch certificate checked against the specified grade |
| Dimensional | Tape and caliper per bundle, both directions, diagonals for squareness |
| Cure | Hardness and tack assessment on sampled panels |
| Surface | Visual and rub check on grit or concave surface |
| Edge sealing | Visual check on every cut and drilled edge |
Dimensional inspection, in detail
Length and width are measured on sampled panels from each bundle. Squareness is checked by comparing the two diagonals, because a squareness error is what produces a visible gap at a joint or a panel that will not drop into a frame.
Bar pitch is measured across ten bars rather than one, so a drift is visible. Bar depth is measured at three points per bar. Open area is checked against the specified figure, 40% or 60% for pultruded sections and the mesh figure for molded.
Load and deflection checks
Where a project specifies a load case, we can set the panel on bearers at the specified span and measure deflection under stepped loading, recording the deflection at each step. This is a check against a stated case, not a certification of a load table.
If a witnessed test is required, it is written into the order with the rig, the load steps and the acceptance deflection agreed in advance. That is the only way a test result means anything to a third party.
What goes to a third-party laboratory
Fire performance and salt spray or chemical exposure testing are carried out by SGS or Intertek rather than in house, because those need accredited facilities and the report has to be independent to be useful.
The consequence is a lead time. If your project needs a specific test on a specific section, raise it at the enquiry stage rather than after production, because a new test cannot be retro-fitted to a finished order.
What the buyer receives
With the order: the packing list with bundle markings, the dimensional inspection sheet, resin batch certificates, and the load table for the section supplied. On request: certificate and third-party report copies, and photographs of the load before the container is sealed.
What we do not issue is a generic certificate of quality covering every panel ever produced. If a document is needed, it is specified in the order and produced for that order.
The limits, stated plainly
We cannot test a property for which no test method has been agreed, and we cannot certify a section we did not produce. Where a buyer needs a figure we have not tested, the answer is a new test with a stated method, not an interpolated number.
Saying this is part of the service. A supplier that promises every figure on request is telling you something about its paperwork, not about its product.
Related pages
- Certifications and verification
- Downloads and document pack
- QC checklist for buying from China
- Grating specifications by mesh