FRP I-Beam — Pultruded GRP Beam
The I-beam is the shape that buys the most stiffness per kilogram, and under a grating deck that is what decides whether a platform feels solid. Pultruded to BS EN 13706 grade E17 or E23, cut to length.
What the section does
An I-beam puts material where it works. The two flanges sit far from the neutral axis and carry the bending moment in tension and compression, while the web carries the shear and holds the flanges apart. Move the same mass into a rectangle and the stiffness falls away; that is why a bearer is an I and not a box.
For a grating deck the beam is almost always the governing member. The panel spans 600 to 1200 mm between bearers; the bearer spans 2 to 6 m between columns or posts, and its deflection is what a person walking feels. If a deck bounces, the panel is rarely the cause.
Where an FRP I-beam is the right choice
- Primary bearers under molded or pultruded grating in chemical, water treatment, marine and offshore environments where a steel beam would need painting and re-painting.
- Platform and walkway frames where the deck has to sit at height and the frame is exposed to the same corrosion as the grating.
- Roof walkways and solar array access routes, where the dead load of a steel bearer is part of the structural calculation and a quarter of the mass is welcome.
- Retrofit of an existing steel frame where the new member must be installed by two people without a crane.
How the section is checked
Three checks settle most bearer designs, and all three need the same inputs: the span, the load, and the section properties. Bending stress is moment divided by section modulus. Deflection under a uniform load is five times load per length times span to the fourth, divided by 384 times modulus times second moment of area. Shear in the web is the shear force divided by web area, and it almost never governs a pultruded GRP beam.
The modulus is the number people forget to ask for. Grade E17 and grade E23 differ in declared modulus, and deflection scales inversely with it. A profile sold as "high strength" without a grade cannot be checked, which is why a pultruded beam datasheet should state the grade to BS EN 13706 and the measured modulus beside it.
As a worked example with assumed dimensions rather than a catalogue size: a 100 mm deep I-beam with 10 mm flanges, 6 mm web, checked over a 3 m span at 2 kN per metre. The arithmetic is shown in the specification sheet we send with the quotation, so the buyer can re-run it with their own numbers instead of trusting a table.
Connections and details
Pultruded sections are bolted, not welded. A connection is usually a plate or an angle bolted through the web, with the bolts bearing on the flange edges, and the detail matters more than the section: a beam that is strong in bending can still fail at a connection that puts a point load on a thin flange.
Avoid bearing a concentrated load directly on the flange tip. Where a beam carries a hanging load or a bracket, the load goes through a plate that distributes it across the web depth. Where the beam is exposed to weather, the bolts and plates are stainless, and the two materials are isolated from each other so that no galvanic couple forms at the joint.
Specifying an FRP I-beam
- Depth, flange width, flange thickness and web thickness as a drawing, not as a trade name.
- Grade to BS EN 13706, stated as E17 or E23, plus the measured modulus.
- Resin system: isophthalic polyester for general structural, vinyl ester where chemical exposure or higher temperature is involved.
- Length and cut tolerance, and whether the ends are square cut or prepared for a specific connection.
- Colour and surface: a UV-stable surface finish is not cosmetic on an outdoor deck, it is what keeps the profile from chalking and the glass from showing.
- Fire requirement, if the structure is inside a plant where a flame spread class applies.
Related pages
- GRP structural profiles overview
- FRP channel
- FRP angle
- FRP square tube
- All FRP profiles
- FRP grating span and load calculator
FAQ
FRP H Beam and FRP Wide Flange Beam: Load-Bearing Pultruded Sections for Long Spans
The FRP H Beam and the heavier FRP Wide Flange Beam are the load-bearing heart of a pultruded grating platform. Because E-glass rovings run continuously along the length, these sections carry bending load at a fraction of the weight of a steel IPE of equal stiffness — typically 75% lighter — and they never rust in splash zones, cooling-tower decks or coastal walkways.
Fiberglass I-Beam vs Steel IPE: Why Fiberglass Structural Beams for Industrial Frame Applications Win on Weight
A Fiberglass I-Beam is selected when deflection governs rather than ultimate strength. We supply E17 / E23 modulus sections to BS EN 13706 and declare the modulus where the span-to-depth ratio is tight. Fiberglass Structural Beams for Industrial Frame builds, machine guarding and access platforms are cut to a length list, drilled at the connection points and supplied with prepared ends. See also the FRP pultruded profiles range and the structural profiles library.
How Pultrusion Builds a Beam: Roving, Veil and Wall Tolerance
Each beam is pulled through a heated die: 60–75% by weight of continuous E-glass roving for axial stiffness, a surfacing veil for a resin-rich corrosion skin, and a choice of isophthalic polyester, vinylester or polyurethane resin. Wall thickness and flange width are held to pultrusion tolerances, and sections are flame-retardant to ASTM E84 Class 1 where specified. We are a direct FRP manufacturer (founded 2004, 20,000+ m² plant, 40+ export countries); stock sections ship in 7–35 working days.