verifying how much panel rests on each support and how far it may safely overhang
- Measure the support width and the panel's resting contact on each side.
- Confirm the panel edge bears on the beam rather than hanging beyond it.
- Check that clips can land on a solid bearing point at every support.
1. Scope and Engineering Context
How far a panel rests on its beam matters as much as the section itself: an edge that seats only narrowly concentrates contact and can rock or bruise under traffic, while an edge left hanging past the support acts as an unplanned cantilever. Bearing is checked on the node detail and the actual beam width before panels are fixed.
The survey records the support width on each side, the panel edge contact, and any tip projecting beyond the beam. Clips need a solid seat under them; an edge clip over open space does not substitute for bearing on framing.
- bearing length. The length of panel edge resting on a beam, measured along the spanning direction; it sets how firmly the edge is seated.
- overhang. The panel tip projecting past the support line; beyond the standard detail this becomes a cantilever condition.
- edge bearing. The contact made where the panel edge meets the beam, checked for width and level rather than assumed from the drawing.
- support contact. The point where panel and support touch; clips and edge closure must land on this solid contact.
- panel edge. The trimmed or factory edge of a panel, which must trace back to a beam rather than finish over a void.
2. Worked Example and Site Checklist
Use the verified panel mass to frame the bearing check. A standard molded sheet measures 1220 × 3660 mm; a 38 mm molded panel weighs about 87 kg, with a data-sheet weight near 19.5 kg/m². That edge load has to sit on real beam contact, not on an overhanging tip.
The exact minimum bearing length is not published in the verified load rows; it follows the installation node detail and the support width on the project drawing. Where the beam is too narrow or the edge projects past it, the dimension goes to engineer review rather than being closed by a guessed minimum.
| Check on site | What to record | Why it matters |
|---|---|---|
| Measure support width on each side | Record beam flange or rail width under the panel edge | Bearing length is bounded by how wide the support actually is. |
| Confirm edge contact on the beam | Note whether the panel edge seats fully or hangs past | An edge over the void loses the support the rating assumes. |
| Check clip seat on solid bearing | Mark where each clip lands on framing | A clip over open space cannot hold an unsupported edge. |
| Measure any projecting tip | Record overhang beyond the support line | A cantilevered end is outside the uniform-load table. |
| Flag narrow or missing bearing | List edges needing wider support or a node detail | Poor bearing is corrected before fixing, not after traffic begins. |
| Item | Verified figure / note |
|---|---|
| Standard molded panel | 1220 × 3660 mm |
| 38 mm molded panel | About 87 kg per full sheet |
| 38 mm molded weight | About 19.5 kg/m² |
| Minimum bearing length | Per node detail / support width; engineer review if not stated |
3. Failure Modes and Cautions
A typical fault is narrow bearing: the panel edge touches only the beam's corner, so contact concentrates at a thin strip and the deck rocks underfoot. Local bruising and edge damage follow, even when the panel section itself looks adequate; the deficiency is bearing width, not depth.
The reverse fault is an overhanging panel end treated as ordinary bearing. The tip past the beam acts as a cantilever under load, sagging and deflecting in a way the simply supported load row does not rate. That projection needs a separate structural review, not a clip added on site.
- Verify bearing on both edges of a panel; one seated side does not rescue an overhanging other.
- Match the panel edge to the node detail before ordering cut sections.
- Record support level, width and edge contact in the pre-installation survey.
4. Boundary: When This Does Not Apply
This bearing check applies to panels on discrete framing under uniform walkway load. It does not settle cantilevered projections, wind-uplift or pull-out fixing, seismic anchors, concentrated point or wheel loads, or edge impact from moving equipment; those require an independent structural assessment.
Where a panel crosses a channel or trench with bearing only along one rim, treat it as a cover detail rather than a bearing-span check. An unsupported tip over a void must follow an engineered edge detail; bearing assumptions from a framed deck do not carry over.
5. Frequently Asked Questions
How much should grating sit on the beam?
The panel must bear fully on the support line with a defined edge contact; the exact bearing follows the node detail and support width. Do not leave an edge bar hanging unsupported.
Is panel overhang ever allowed?
Overhang beyond the design detail is a cantilever condition and is not settled by the uniform load table. It requires a separate structural review.
What happens when bearing is too narrow?
Narrow bearing concentrates contact at the edge and can leave the panel prone to rocking or local damage. Confirm beam width and clip placement together.
Where are bearing details shown?
Bearing and node contact details are in the installation node drawings; match the panel edge to those details before ordering cut sections.
Should bearing be checked on site?
Yes, verify support level, bearing width and edge contact during the pre-installation survey rather than discovering poor bearing after panels are fixed.