FRP/GRP Grating Specification · Cable Trench Cover
38 mm Molded FRP/GRP Grating, 50 x 50 mm Mesh, Concave Top for Cable Trench Cover
38 mm molded FRP/GRP grating, 50 x 50 mm open mesh configured with a concave top for cable trench cover. The verified span-load values below support an initial selection; final section and resin are confirmed against your drawing, medium and support layout.
Specification
| Product type | Molded FRP/GRP grating |
|---|---|
| Mesh | 50 x 50 mm |
| Depth | 38 mm |
| Standard panel | 1220 x 3660 mm, cut to size |
| Open area | confirm_with_factory |
| Unit weight | confirm_with_factory |
| Recommended resin | Isophthalic polyester |
| Surface | Concave (meniscus) top |
| Bar orientation | Bidirectional molded lay-up with a wider opening, intended for drainage, ventilation and spill decks rather than fine-foot retention. |
Allowable uniform load by support span
| Support span | Allowable UDL (kN/m²) |
|---|---|
| 600 mm | 22 kN/m² |
| 900 mm | 10 kN/m² |
| 1200 mm | 5.5 kN/m² |
Values are verified allowable uniform loads for a simply supported single span at L/200 deflection. They are an initial selection aid, not a project design certification; wheel loads, point loads, cantilevers, edge cuts and concentrated equipment loads require separate engineering review. Weight and open area not present in the verified data are marked confirm_with_factory and are not estimated.
Selection rationale
Covers over cable trenches and cable runs in process plants and substations. Light foot traffic and equipment access over buried or routed cables; non-conductive, corrosion-resistant deck
This 38 mm 50 x 50 molded section targets drainage, ventilation and spill decks. The verified L/200 simple-span ratings are 22, 10 and 5.5 kN/m² at 600, 900 and 1200 mm respectively, checked against the bearer spacing. Heavy rolling, point loads and cantilevers outside the verified table require separate engineering review.
The concave face channels water away from the walking line; no bonded grit layer is added. On site the panel follows the section direction; fixing clips and bearing are verified against the layout.
Cutouts and edges are finished after layout confirmation; the walking condition governs the finish choice.
Section profile and fixing
The 38 mm 50 x 50 mesh opens the deck to pass water, vapour and small debris, while still carrying the molded-section load class on fewer bearing bars. Bidirectional molded lay-up; lay the panel to the channel or equipment line, secure with non-corrosive clips, and confirm cutout edges against the drawing.
Surface finish
The meniscus-shaped concave top drains water away from the contact patch and grips wet footwear without an added grit layer. General wet walkways, drainage decks and outdoor routes that remain drained under normal use.
Data availability
Weight per square metre and open mesh percentage for the 38 mm molded 50 x 50 concave cable trench cover are not in the verified matrix and must be confirmed with the factory. Supplying them unlocks the self-weight check for bearer design and the passage-area calculation; the listed UDL values still guide the initial choice.
Resin selection
Isophthalic polyester. Isophthalic polyester covers wastewater, seawater, mild acid and moist atmospheric service within the listed temperature bound.
Final resin is set against the contact medium, concentration and temperature; media outside the guide are confirmed in writing.
Installation, fixing and delivery
Panels are standard 1220 x 3660 mm, cut to size on request, and fixed with M/C/L/Z FRP clips or non-corrosive fasteners to the support frame; pultruded bars span between supports in the load direction. Edges and cut openings are finished by the factory after the drawing and cutout positions are confirmed.
Standard-size production runs about 15–25 days; overall delivery, including fabrication, packaging and shipping, is typically 12–36 working days by destination. MOQ is 10 m²; fabrication drawings are confirmed before production.
Request-for-quotation inputs
- Overall dimensions and required panel layout
- Support spacing / clear span and beam layout
- Design load: uniform, wheel or point load, and expected use
- Resin requirement and contact medium, concentration and temperature
- Surface finish (concave, grit or smooth)
- Quantity in square metres
- Destination country and any local standard to follow
Typical uses
- cable trench cover
- molded cable trench cover
- concave-top cable trench cover
- industrial personnel walkway
- corrosion-resistant platform deck
- open-mesh drainage and ventilation deck