FRP Grating Specifications

25 mm T-Bar Pultruded FRP Grating

The lightest pultruded section in common use: a 25 mm bearing bar on a 38 mm pitch, sized for walkways and platforms with spans up to about two metres.

Technical specifications

TypePultruded FRP grating, T-bar section
Bearing bar depth25 mm (1 in)
Top flange width15 mm
Bar pitch38 mm (1.5 in) standard
Open areaabout 40% (clear 15 mm) or about 60% (clear 23 mm)
Unit weightabout 9.5 kg/m² at 40% open; about 7.5 kg/m² at 60% open
Standard panel1220 x 3660 mm (4 x 12 ft), cut to size
Resin systemsIsophthalic polyester; vinyl ester for acid and chloride service; phenolic for fire-critical work
SurfaceSmooth, concave, or quartz-grit anti-slip
FixingM-clip, C-clip, L-clip or stainless saddle; no drilling of the bearing bar

Load and span guidance

Support spanIndicative UDL, 40% openIndicative UDL, 60% openDeflection basis
1.5 mabout 560 kg/m²about 450 kg/m²L/200
2.0 mabout 310 kg/m²about 250 kg/m²L/200
2.5 mabout 190 kg/m²about 150 kg/m²L/200
3.0 mabout 120 kg/m²about 95 kg/m²L/200

Indicative figures for early sizing, assuming a simply supported single span, uniform load and no propping. Allowable load for a project is confirmed from our certified load table for the selected section, resin and deflection limit, in line with DIN 24537-3. Where L/300 or a trolley point load is specified, deflection normally governs rather than material stress.

Why a 25 mm T-section

The T profile puts material where it resists bending, a 15 mm top flange bonded to a vertical web, so a 25 mm deep bar carries a walkway load over one and a half to two metres using very little material. At 7.5 to 9.5 kg/m² it is the lightest option we supply, which matters when the structure underneath is a retrofitted mezzanine, a tank top or an access platform on an existing frame with limited spare capacity.

The trade-off is torsional stiffness. A T-bar resists a load applied between two bearing bars mainly through the top flange, so it is comfortable under foot traffic and uniform load but less tolerant of a heavy concentrated load sitting directly on one bar. On long spans, on platforms carrying trolleys, or where the panel is supported only at its two ends, the I-bar section is the more honest choice, and we will say so at quotation stage rather than sell the lighter section.

Where it fits

  • Walkways and access platforms on steel or concrete framing
  • Mezzanine and maintenance platforms in warehouses and plant rooms
  • Cable trench and drainage covers where 40% open area still drains
  • Light-duty stair treads when fitted with a nosing
  • Wet-process areas with vinyl ester resin for acid and chloride exposure

Panels are cut to the opening, laid across the bearers and locked with clips, so no bearing bar is drilled and no hot work is needed. Clips are specified at roughly one per 300 to 400 mm of panel edge, plus a clip at every intermediate bearer crossing.

Related resources

FAQ

W
F
S
C
H
A
I
T
C
Y
W
M

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to [email protected]. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: [email protected]