FRP Grating Specifications

25 mm I-Bar Pultruded FRP Grating

A 25 mm I-section bar: the lower flange resists twisting, so the light depth survives concentrated loads that would distort a plain T-bar.

Technical specifications

TypePultruded FRP grating, I-bar section
Bearing bar depth25 mm (1 in)
SectionI profile, top and bottom flange bonded to a central web
Bar pitch38 mm (1.5 in) standard
Open areaabout 40% (clear 15 mm) or about 60% (clear 23 mm)
Unit weightabout 10.5 kg/m² at 40% open; about 8.5 kg/m² at 60% open
Standard panel1220 x 3660 mm (4 x 12 ft), cut to size
Resin systemsIsophthalic polyester; vinyl ester for chemical service; phenolic on request
SurfaceConcave standard; grit and smooth available
FixingM-clip or C-clip with SS304 or SS316 bolts; saddle at panel ends

Load and span guidance

Support spanIndicative UDL, 40% openIndicative UDL, 60% openDeflection basis
1.5 mabout 640 kg/m²about 520 kg/m²L/200
2.0 mabout 355 kg/m²about 285 kg/m²L/200
2.5 mabout 215 kg/m²about 170 kg/m²L/200
3.0 mabout 140 kg/m²about 110 kg/m²L/200

Indicative values for a simply supported span under uniform load. The I-bar section behaves better than a T-bar of the same depth under eccentric and point loading, which is why it is preferred where the load is not evenly spread. Confirmed values come from our certified load table.

The lower flange does the work

A grating bar fails in two different ways: it bends, and it twists. A T-bar has its material at the top, so a load applied between two bars tends to roll the bar about its own axis. The I-section adds a bottom flange, which raises torsional stiffness dramatically for a few grams of resin per metre and keeps the walking surface flat under a foot placed off-centre.

At 25 mm depth the I-bar therefore keeps the light-section economy while removing the two objections that owners raise about a shallow T-bar, namely a springy feel under a single footfall and a bar that creeps out of line after a few years of heavy traffic. If the platform is narrow, hand-loaded and carries people who stop to work rather than walk through, this is the section to specify at this depth.

Where it fits

  • Narrow access platforms and inspection walkways
  • Stair treads and landings where footfall is concentrated
  • Laboratory and clean-area platforms needing a flat, even deck
  • Covers over service trenches crossed by maintenance staff
  • Light platforms inside vessels and tanks, where weight matters

Because the lower flange sits below the neutral axis, the panel must be supported on bearers that do not contact the bottom flange. A bearer with a rough or high weld bead will load the lower flange unevenly, so bearers should be checked for flatness before panels are laid.

Related resources

FAQ

I
U
W
W
W
A
D
I
C
Y
W
S

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to [email protected]. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: [email protected]