25 mm I-Bar Pultruded FRP Grating
A 25 mm I-section bar: the lower flange resists twisting, so the light depth survives concentrated loads that would distort a plain T-bar.
Technical specifications
| Type | Pultruded FRP grating, I-bar section |
|---|---|
| Bearing bar depth | 25 mm (1 in) |
| Section | I profile, top and bottom flange bonded to a central web |
| Bar pitch | 38 mm (1.5 in) standard |
| Open area | about 40% (clear 15 mm) or about 60% (clear 23 mm) |
| Unit weight | about 10.5 kg/m² at 40% open; about 8.5 kg/m² at 60% open |
| Standard panel | 1220 x 3660 mm (4 x 12 ft), cut to size |
| Resin systems | Isophthalic polyester; vinyl ester for chemical service; phenolic on request |
| Surface | Concave standard; grit and smooth available |
| Fixing | M-clip or C-clip with SS304 or SS316 bolts; saddle at panel ends |
Load and span guidance
| Support span | Indicative UDL, 40% open | Indicative UDL, 60% open | Deflection basis |
|---|---|---|---|
| 1.5 m | about 640 kg/m² | about 520 kg/m² | L/200 |
| 2.0 m | about 355 kg/m² | about 285 kg/m² | L/200 |
| 2.5 m | about 215 kg/m² | about 170 kg/m² | L/200 |
| 3.0 m | about 140 kg/m² | about 110 kg/m² | L/200 |
Indicative values for a simply supported span under uniform load. The I-bar section behaves better than a T-bar of the same depth under eccentric and point loading, which is why it is preferred where the load is not evenly spread. Confirmed values come from our certified load table.
The lower flange does the work
A grating bar fails in two different ways: it bends, and it twists. A T-bar has its material at the top, so a load applied between two bars tends to roll the bar about its own axis. The I-section adds a bottom flange, which raises torsional stiffness dramatically for a few grams of resin per metre and keeps the walking surface flat under a foot placed off-centre.
At 25 mm depth the I-bar therefore keeps the light-section economy while removing the two objections that owners raise about a shallow T-bar, namely a springy feel under a single footfall and a bar that creeps out of line after a few years of heavy traffic. If the platform is narrow, hand-loaded and carries people who stop to work rather than walk through, this is the section to specify at this depth.
Where it fits
- Narrow access platforms and inspection walkways
- Stair treads and landings where footfall is concentrated
- Laboratory and clean-area platforms needing a flat, even deck
- Covers over service trenches crossed by maintenance staff
- Light platforms inside vessels and tanks, where weight matters
Because the lower flange sits below the neutral axis, the panel must be supported on bearers that do not contact the bottom flange. A bearer with a rough or high weld bead will load the lower flange unevenly, so bearers should be checked for flatness before panels are laid.