ADA Compliant 38 mm Pultruded FRP Grating
A 38 mm pultruded section detailed so that floor openings stay within the accessible walking-surface limit.
Technical specifications
| Type | Pultruded FRP grating, accessible walking surface |
|---|---|
| Bearing bar depth | 38 mm |
| Clear opening | about 13 mm, within the ADA 1/2 in limit, or the smaller option for stricter local codes |
| Open area | about 34% with the restricted opening |
| Unit weight | about 16 kg/m² |
| Standard panel | 1220 x 3660 mm, cut to size |
| Resin systems | Isophthalic polyester; vinyl ester; phenolic on request |
| Surface | Concave or grit; grit recommended on ramps and public routes |
| Fixing | Clip system with SS304 bolts; flush transitions at doorways |
| Compliance note | Final compliance depends on the complete route, not on the deck alone |
Load and span guidance
| Support span | Indicative UDL, ADA opening | Indicative UDL, 40% standard opening | Deflection basis |
|---|---|---|---|
| 2.0 m | about 330 kg/m² | about 520 kg/m² | L/200 |
| 2.5 m | about 210 kg/m² | about 330 kg/m² | L/200 |
| 3.0 m | about 140 kg/m² | about 220 kg/m² | L/200 |
| 3.5 m | about 100 kg/m² | about 150 kg/m² | L/200 |
Indicative values for a single simply supported span. The restricted opening reduces open area and adds bar material, which slightly raises unit weight and reduces capacity per square metre compared with a standard 40% deck.
What an accessible deck actually has to satisfy
The ADA rule that governs grating is the walking-surface opening limit: floor openings must not pass a 13 mm sphere, so that a cane tip, a heel or a wheel cannot drop in. A standard 38 mm pitch with 23 mm clear opening does not meet that, so the deck is detailed with a restricted clear opening of about 13 mm, which brings open area down to roughly 34% and the unit weight up to about 16 kg/m².
Compliance is a property of the route, not of the panel. A compliant deck that meets a 20 mm step at the doorway, a ramp without a landing, or a handrail at the wrong height is not a compliant route. We supply the deck and the fixing detail, and we will say plainly that the transition details and the ramp geometry have to be checked against the local code by whoever is signing the accessibility statement.
Where it fits
- Public and staff access routes in buildings and plants
- Ramps and landings on accessible exterior routes
- Rail, transit and airport maintenance walkways
- Pool and leisure centre surrounds with barefoot traffic
- Any deck where a cane tip or wheelchair caster must not drop in
Transitions at doorways and landings should be flush, and the deck should be fixed so no panel edge lifts under a wheelchair caster. Clip spacing follows the load table, and the grit surface is applied to any route with a slope.