📞 Contact UsHomeProductsCatalogueApplicationsProjectsMarketsBlog🎬 VideosTools💰 CalculatorAbout
FRP Grating Specifications

ADA Compliant 38 mm Pultruded FRP Grating

A 38 mm pultruded section detailed so that floor openings stay within the accessible walking-surface limit.

Technical specifications

TypePultruded FRP grating, accessible walking surface
Bearing bar depth38 mm
Clear openingabout 13 mm, within the ADA 1/2 in limit, or the smaller option for stricter local codes
Open areaabout 34% with the restricted opening
Unit weightabout 16 kg/m²
Standard panel1220 x 3660 mm, cut to size
Resin systemsIsophthalic polyester; vinyl ester; phenolic on request
SurfaceConcave or grit; grit recommended on ramps and public routes
FixingClip system with SS304 bolts; flush transitions at doorways
Compliance noteFinal compliance depends on the complete route, not on the deck alone

Load and span guidance

Support spanIndicative UDL, ADA openingIndicative UDL, 40% standard openingDeflection basis
2.0 mabout 330 kg/m²about 520 kg/m²L/200
2.5 mabout 210 kg/m²about 330 kg/m²L/200
3.0 mabout 140 kg/m²about 220 kg/m²L/200
3.5 mabout 100 kg/m²about 150 kg/m²L/200

Indicative values for a single simply supported span. The restricted opening reduces open area and adds bar material, which slightly raises unit weight and reduces capacity per square metre compared with a standard 40% deck.

What an accessible deck actually has to satisfy

The ADA rule that governs grating is the walking-surface opening limit: floor openings must not pass a 13 mm sphere, so that a cane tip, a heel or a wheel cannot drop in. A standard 38 mm pitch with 23 mm clear opening does not meet that, so the deck is detailed with a restricted clear opening of about 13 mm, which brings open area down to roughly 34% and the unit weight up to about 16 kg/m².

Compliance is a property of the route, not of the panel. A compliant deck that meets a 20 mm step at the doorway, a ramp without a landing, or a handrail at the wrong height is not a compliant route. We supply the deck and the fixing detail, and we will say plainly that the transition details and the ramp geometry have to be checked against the local code by whoever is signing the accessibility statement.

Where it fits

  • Public and staff access routes in buildings and plants
  • Ramps and landings on accessible exterior routes
  • Rail, transit and airport maintenance walkways
  • Pool and leisure centre surrounds with barefoot traffic
  • Any deck where a cane tip or wheelchair caster must not drop in

Transitions at doorways and landings should be flush, and the deck should be fixed so no panel edge lifts under a wheelchair caster. Clip spacing follows the load table, and the grit surface is applied to any route with a slope.

Related resources

FAQ

D
N
W
T
D
S
I
I
C
Y
W
T

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to [email protected]. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: [email protected]