18% Open Area Pultruded FRP Grating
A dense bar layout at roughly 18% open area: more material, more load, and far less that can fall through.
Technical specifications
| Type | Pultruded FRP grating, dense bar layout |
|---|---|
| Bearing bar depth | 25 mm or 38 mm |
| Bar pitch | 28 mm with a clear opening of about 5 mm |
| Open area | about 18% |
| Unit weight | about 14 kg/m² at 25 mm depth; about 20 kg/m² at 38 mm depth |
| Standard panel | 1220 x 3660 mm, cut to size |
| Resin systems | Isophthalic polyester; vinyl ester; phenolic on request |
| Surface | Concave or grit; smooth for hygienic areas |
| Fixing | Standard clip family; denser clip pattern at panel edges |
| Typical duty | Heavy foot traffic, small dropped objects, hygiene and heel safety |
Load and span guidance
| Support span | Indicative UDL, 25 mm depth | Indicative UDL, 38 mm depth | Deflection basis |
|---|---|---|---|
| 1.5 m | about 620 kg/m² | about 900 kg/m² | L/200 |
| 2.0 m | about 350 kg/m² | about 520 kg/m² | L/200 |
| 2.5 m | about 210 kg/m² | about 320 kg/m² | L/200 |
| 3.0 m | about 140 kg/m² | about 215 kg/m² | L/200 |
Indicative values for a simply supported span under uniform load. The dense bar layout raises capacity per square metre mainly because there are more bars sharing the load, not because each bar is stronger. Certified values are supplied per project.
Where open area is the problem, not the benefit
Open area is usually sold as an advantage, because it drains and ventilates. On some decks the opposite is true: a bottling line where a cap must not fall into the drain below, a food area where hygiene rules forbid open holes, a stair where a heel could pass through, or a platform above a walkway where dropped tools are a hazard. Filling that gap with a heavy steel plate defeats the purpose, since the plate corrodes and weighs more than the grating it replaces.
At about 18% open the same corrosion-resistant deck stops nearly everything a boot, a bolt or a bottle cap could drop, while still draining rain and wash-down water. The cost is weight and open area, so it is specified where the drop-through risk or the hygiene rule is the deciding constraint, and not as a general-purpose deck.
Where it fits
- Food, beverage and pharmaceutical areas with hygiene requirements
- Platforms above walkways where dropped tools are a hazard
- Stair treads where heel passage must be prevented
- Bottling, filling and packaging lines over drainage channels
- Small-parts assembly areas and inspection benches
Dense panels are heavier than standard ones, so two-person handling still applies at 1220 x 3660 mm but a spreader is advisable at 38 mm depth. Wash-down areas need the cut edges sealed and the clips specified in SS316.