📞 Contact UsHomeProductsCatalogueApplicationsProjectsMarketsBlog🎬 VideosTools💰 CalculatorAbout
FRP Grating Specifications

18% Open Area Pultruded FRP Grating

A dense bar layout at roughly 18% open area: more material, more load, and far less that can fall through.

Technical specifications

TypePultruded FRP grating, dense bar layout
Bearing bar depth25 mm or 38 mm
Bar pitch28 mm with a clear opening of about 5 mm
Open areaabout 18%
Unit weightabout 14 kg/m² at 25 mm depth; about 20 kg/m² at 38 mm depth
Standard panel1220 x 3660 mm, cut to size
Resin systemsIsophthalic polyester; vinyl ester; phenolic on request
SurfaceConcave or grit; smooth for hygienic areas
FixingStandard clip family; denser clip pattern at panel edges
Typical dutyHeavy foot traffic, small dropped objects, hygiene and heel safety

Load and span guidance

Support spanIndicative UDL, 25 mm depthIndicative UDL, 38 mm depthDeflection basis
1.5 mabout 620 kg/m²about 900 kg/m²L/200
2.0 mabout 350 kg/m²about 520 kg/m²L/200
2.5 mabout 210 kg/m²about 320 kg/m²L/200
3.0 mabout 140 kg/m²about 215 kg/m²L/200

Indicative values for a simply supported span under uniform load. The dense bar layout raises capacity per square metre mainly because there are more bars sharing the load, not because each bar is stronger. Certified values are supplied per project.

Where open area is the problem, not the benefit

Open area is usually sold as an advantage, because it drains and ventilates. On some decks the opposite is true: a bottling line where a cap must not fall into the drain below, a food area where hygiene rules forbid open holes, a stair where a heel could pass through, or a platform above a walkway where dropped tools are a hazard. Filling that gap with a heavy steel plate defeats the purpose, since the plate corrodes and weighs more than the grating it replaces.

At about 18% open the same corrosion-resistant deck stops nearly everything a boot, a bolt or a bottle cap could drop, while still draining rain and wash-down water. The cost is weight and open area, so it is specified where the drop-through risk or the hygiene rule is the deciding constraint, and not as a general-purpose deck.

Where it fits

  • Food, beverage and pharmaceutical areas with hygiene requirements
  • Platforms above walkways where dropped tools are a hazard
  • Stair treads where heel passage must be prevented
  • Bottling, filling and packaging lines over drainage channels
  • Small-parts assembly areas and inspection benches

Dense panels are heavier than standard ones, so two-person handling still applies at 1220 x 3660 mm but a spreader is advisable at 38 mm depth. Wash-down areas need the cut edges sealed and the clips specified in SS316.

Related resources

FAQ

W
A
I
Y
D
P
C
Y
W
I
W
2

Document Preview

Preview mode · For full document, click Download

Download Document

Thank you for your interest. Please fill in your email and company name. Our technical and sales team will contact you within 30 minutes (during working hours) to provide support!

📧 Your information will be sent to [email protected]. We respect your privacy and will never share your data.

Thank You!

Your request has been received successfully.

Our technical and sales team will contact you within 30 minutes (during working hours) to provide the document and professional support!

If you need urgent assistance, please email: [email protected]